85264189988003 © SANYO 2007
Contents
Page
IMPORTANT!
Please Read Before Starting .................................. 2
1. GENERAL .......................................................... 3
1-1. Tools Required for Installation (not supplied)
1-2. Accessories Supplied with Unit
1-3. Optional Copper Tubing Kit
1-4. Type of Copper Tube and Insulation Material
1-5. Additional Materials Required for Installation
2. INSTALLATION SITE SELECTION ................... 4
2-1. Indoor Unit
2-2. Outdoor Unit
2-3. Baffle Plate for the Outdoor Unit
3. HOW TO INSTALL THE INDOOR UNIT ............. 9
3-1. Remove the Rear Panel from the Unit
3-2. Make a Hole
3-3. Install the Rear Panel on the Wall
3-4. Remove the Grille to Install the Indoor Unit
3-5. Shape the Indoor Side Tubing
3-6. Wiring Instructions
3-7. Recommended Wire Length and Diameter
3-8. Wiring Instructions for Inter-unit Connections
3-9. Mounting
3-10. Drain Hose
4. HOW TO INSTALL THE OUTDOOR UNIT ....... 19
4-1. Wiring Instructions for the Outdoor Unit
5. REFRIGERANT TUBING .................................. 20
5-1. Use of the Flaring Method
5-2. Flaring Procedure with a Flare Tool
5-3. Caution before Connecting Tubes Tightly
5-4. Connecting Tubing between Indoor and
Outdoor Units
5-5. Insulation of Refrigerant Tubing
5-6. Taping the Tubes
5-7. Finishing the Installation
6. AIR PURGING................................................... 22
I Air Purging with a Vacuum Pump (for Test Run)
I Basic Functions of the Service Valves
I Pump Down
INSTALLATION INSTRUCTIONS
Model Combinations
Combine indoor and outdoor units only as listed
below.
Indoor Unit Outdoor Unit
KS1872 C1872
CL1872
KS2472 C2472
CL2472
Power Source:
60 Hz, single-phase, 230/208 V
– Inverter Split System Air Conditioner –
COOL/DRY Model
This air conditioner uses the new refrigerant R410A.
Be sure to read the yellow instruction sheet
attached to the outdoor unit for models using the
new refrigerant R410A.
The illustrations are based on the typical appearance of
a standard model. Consequently, the shape may differ
from that of the air conditioner that you are installing.
NOTE
7. REMOTE CONTROL UNIT INSTALLATION
POSITION ......................................................... 26
7-1. Mounting on a Wall
8. ADDRESS SWITCH .......................................... 27
8-1. Address Setting of the Remote
Control Unit
SANYO Commercial Solutions In Canada
A Division of SANYO North America Corporation SANYO Canada Inc.
Cornerstone Business Park, 1-300 Applewood Crescent, Concord
1062 Thorndale Avenue, Ontario, L4K 5C7, Canada
Bensenville, IL 60106, U.S.A.
W
Refrigerant service valve size = 5/16"
NOTE
07-154 CL1872-2472 6/12/07 3:19 PM Page a

Other manuals for Sanyo 18KLS72

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sanyo 18KLS72 and is the answer not in the manual?

Sanyo 18KLS72 Specifications

General IconGeneral
Capacity1.5 Ton
Power Supply220-240V, 50Hz
RefrigerantR410A
Noise Level (Outdoor)52 dB
Net Weight (Indoor Unit)12 kg
TypeSplit
Cooling Capacity18000 BTU/hr
Noise Level (Indoor)42 dB
Dimensions (Outdoor Unit)780 x 540 x 240 mm