Page #12 background imageLoading...
Page #12 background image
9
6. ELECTRICAL DATA
6-1. Electric Wiring Diagram
Outdoor Unit SAP–CMRV3143GJ
CAUTION
WHT
YEL
YEL
YEL
YEL
YEL
YEL
BLK
WHT
BLK
BLK
BLK
BLK
BLK
BLK
BLK
YEL
YEL
WHT
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
WHT
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
WHT
BLK
YEL
PNK
WHT
YEL
BLU
WHT
WHT
(WHT)
PRY
(WHT)
CT
L1 L2
(WHT)
PAM
WHT
WHT
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
RED
WHT
FERRITE CORE
WHT
WHT
THERMISTOR(ROOM D WIDE PIPE)
THERMISTOR(ROOM D NARROW PIPE)
THERMISTOR(ROOM C NARROW PIPE)
THERMISTOR(ROOM C WIDE PIPE)
WHT
RED
U V W
GRN/YEL
BLU
EARTH
UNIT D
INDOOR
UNIT C
INDOOR
UNIT B
INDOOR
WHT
GRN/YEL GRN/YEL GRN/YEL GRN/YEL
GRN/YEL
WHT
BLK
BLK
BLK
BLK
BLK
BASE(16P)
TERMINAL
TRANSISTOR
DIODE
BRIDGE DIODE
MECHANICAL VALVE
THERMISTOR(ROOM B NARROW PIPE)
THERMISTOR(ROOM B WIDE PIPE)
CONTROL PCB
UNIT A
INDOOR
YEL
GRY
WHT
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
FILTER PCB
HS
CM
ORG
31 5 7 9
BRN
TERMINAL BASE(3P)
1
AC220V
240V
AC200-L2
TH11
TH10
BLK
YEL
YEL
BLK
4321
TH9
TH8
YEL
YEL
YEL
4321
TH7
TH6
YEL
YEL
YEL
4321
TH5
TH4
TH2
TH1
WHT
6
ORG
BLU
BRN
YEL
RED
1 54326
1 2 3 4 1 2 1 2 1 33 45 6 7 8 9
10
7 8
1110
RED
BLU
ORG
WHT
YEL
BRN
1
C0
3
GRY
+
MC01
MC02
ORG
GRY
6
TH3
1
31 21 54 7621
31 21 54 7621
WHT
HIC PCB
YEL
BLU
BRN
YEL
YEL
RED
WHT
YEL
YEL
+
54321
CN37
MVA
MVAMMV MVB MVC MVD
BRN
RED
YEL
ORG
BLU
6
WHT
(BLK)
BRN
WHT
RE1 RE2
RE1 RE2
D
TR
BD
6
ORG
RED
4
FMO
321
YEL
BLU
WHT
BRN
GRY
GRN/YEL
BLK
1 3 1 5 73 1 2 3 4 5 1 2 3 4 1 2
GRY
WHT
31 5
AC200-L1G1 G2
DC280-
DC280+
1 2 3 4 55432
SOLDERED TERMINAL
TERMINAL
TERMINAL BASE
CONNECTOR
THERMISTOR(ROOM A WIDE PIPE)
THERMISTOR(ROOM A NARROW PIPE)
THERMISTOR(COMPRESSOR TEMP)
THERMISTOR(OUTDOOR TEMP)
THERMISTOR(HEAT EXCHANGER)
BOARD-IN-WIRE
HEAT SINK
REACTOR
MAIN MOTOR OPERATED VALVE
FAN MOTOR
COMPRESSOR MOTOR
OPERATION CONDENSER
TH3
TH4
TH5
TH6
TH7
TH8
TH9
TH10
TH11
TH2
TH1
BD
CM
C0
D
FC1
,
2
FM0
HS
MMV
MVA MVD
RE1
,
2
TR
DESCRIPTION
SYMBOLS
ELECTRIC WIRING DIAGRAM
1 2 3 4 1 2 1 23 45 6 7 8 9
10
7 8
1110
49C
CN31
(BLU)
HIC3
CN18
(WHT)
HIC2
CN30
(WHT)
(WHT)
CN02
HIC2
(WHT)
CN03
HIC3
(WHT)
CN01
HIC1
HIC
+
HIC
-
FC2
HIC
+
HIC
-
HIC1
CN34
(WHT)
PAM
CN23
(WHT)
CT
CN08
(WHT)
PRY
CN21
(RED)
DC280
CN01
(WHT)
AC200
CN29
(RED)
SI
CN35
(WHT)
(RED)
CN38
MNB
(WHT)
CN36
MMV
(WHT)
CN09
FM0
(WHT)
CN16
FM0TH
(BLU)
CN39
MVC
(YEL)
CN40
MVD
(EHT)
CN13
COIL/GAIKI
(BLK)
CN19
COMP
(BLK)
CN24
ATH
(RED)
CN22
BTH
(BLU)
CN20
CTH
(YEL)
CN25
DTH
+
+
W
W
W
1 2 4 1 2 4 1 2 4 1 2
1 2
4
1 2 31 2 31 2 31 2 3
++
GRN/YEL
GRN/YEL
WWWWW
WW
W
854-2-5269-182-00-2
MULTIPLE INDOOR UNITS
COOLING ONLY OUTDOOR UNIT FOR FOUR-ROOM
Electric Wiring Diagram for 4-room multi outdoor unit (CMRV3143GJ)
Before replacing PCBs, turn off the power and check that all
lamps on the PCB are off before starting work. Electric shock
will occur if work is performed while the lamps are lit.
Electric Shock

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sanyo SAP-CMRV3143GJ and is the answer not in the manual?

Sanyo SAP-CMRV3143GJ Specifications

General IconGeneral
BrandSanyo
ModelSAP-CMRV3143GJ
CategoryAir Conditioner
LanguageEnglish

Related product manuals