EasyManua.ls Logo

Sanyo SAP-CMRV3143GJ - Page 37

Sanyo SAP-CMRV3143GJ
39 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
34
Single-room operation
Indoor unit
Indoor Unit Capacity (kW)
Conbination
Room A Room B Room C Room D Total Performance Power Input (W) Current (A)
Min. - Max. Min. - Max.
2.8 Cooling 2.8 2.8 1,270 6.0
1.3 - 3.2 990 - 1,360
3.6 Cooling 3.6 3.6 1,420 6.7
1.4 - 3.6 1,010 - 1,430
5 Cooling 5.0 5.0 1,690 8.0
1.5 - 5.8 1,030 - 1,850
7 Cooling 7.0 7.0 1,880 8.9
1.5 - 8.1 1,120 - 2,040
Two-room operation
Indoor unit
Indoor Unit Capacity (kW)
Conbination
Room A Room B Room C Room D Total Performance Power Input (W) Current (A)
Min. - Max. Min. - Max.
2.8+2.8 Cooling 2.80 2.80 5.6 1,710 8.1
1.1 - 6.7 540 - 1,870
2.8+3.6 Cooling 2.80 3.60 6.4 1,780 8.4
1.3 - 7.6 670 - 1,920
3.6+3.6 Cooling 3.60 3.60 7.2 1,840 8.7
1.4 - 8.1 720 - 1,940
2.8+5.0 Cooling 2.80 5.00 7.8 1,880 8.8
1.4 - 8.1 720 - 1,940
3.6+5.0 Cooling 3.60 5.00 8.6 1,920 9.0
1.4 - 10.5 720 - 2,380
2.8+7.0 Cooling 2.55 6.45 9.0 1,940 8.8
1.2 - 10.5 620 - 2,380
Outdoor Unit SAPCMRV3143GJ
2.8: SAP-#MRV93GJ
3.6: SAP-#MRV123GJ
5.0: SAP-#MRV183GJ
7.0: SAP-#MRV243GJ
NOTE
4-Room Outdoor Unit Combination Table