COOLING
Indoor Unit Outdoor Unit Complete Unit
Fan Motor Fan Motor Compressor
Performance at 240V Single phase 50Hz
Rating Conditions Running Amps. A 0.18 0.25 5.67 6.1
Power Input kW 0.040 0.060 1.250 1.35
Full Load Conditions Running Amps. A 0.18 0.25 6.77 7.2
Power Input kW 0.040 0.060 1.500 1.60
Rating Conditions : Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
Outdoor Air Temperature 43°C D.B.
HEATING
Indoor Unit Outdoor Unit Complete Unit
Fan Motor Fan Motor Compressor
Performance at 240V Single phase 50Hz
Rating Conditions Running Amps. A 0.18 0.25 5.57 6.0
Power Input kW 0.040 0.060 1.220 1.32
Full Load Conditions Running Amps. A 0.18 0.25 6.67 7.1
Power Input kW 0.040 0.060 1.450 1.55
Rating Conditions : Indoor Air Temperature 20°C D.B.
Outdoor Air Temperature 7°C D.B. / 6°C W.B.
Full Load Conditions : Indoor Air Temperature 27°C D.B.
Outdoor Air Temperature 24°C D.B. / 18°C W.B.
Indoor Unit SAPK121AHA
Outdoor Unit SAPC121AHA