6
2-2-2. Outdoor Unit
Outdoor Unit SAPC91AHA
Controller PCB POW-C96GH-S
Compressor
Type Rotary (Hermetic)
Compressor model C-R92H5W 80692945-S
Nominal output W 900
Compressor oil ... Amount cc 4GSD-T or SAY-56T ... 550
Coil resistance (Ambient temp. 25°C) C–R : 3.07
C–S : 7.97
Safety devices Type External(OLR A) External(OLR T)
Overload relay MRA99057-9201 CS-7C115
Operating temp. Open °C 145±5 115±3
Close °C 69±11 95±5
Operating amp.(Ambient temp. 25°C) Trip in 6 to 16 sec. at 18A
Run capacitor µF 22.5
VAC 400
Crank case heater
Fan & Fan Motor
Type Propeller
Q'ty ... Dia. 1 ... ø370
Fan motor model ... Q'ty UE6-21AH5PC-S ... 1
No. of poles ... rpm (240 V, High) 6 ... 780
Nominal output W 20
Coil resistance (Ambient temp. 20°C) WHT-BRN : 338.3
WHT-PNK : 389.7
Safety devices Type Thermal fuse
Operating temp. Open °C 145 ± 2
Close °C
Run capacitor µF 1.5
VAC 440
Heat Exch. Coil
Coil Aluminum plate fin / Copper tube
Rows 1
Fin pitch mm 1.2
Face area
m
2
0.333
External Finish Acrylic baked-on enamel finish
DATA SUBJECT TO CHANGE WITHOUT NOTICE.