EasyManua.ls Logo

Sanyo SAP–K91AHA - Key Component Specifications

Sanyo SAP–K91AHA
78 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4
2-2. Major Component Specifications
2-2-1. Indoor Unit
Indoor Unit SAPK91AHA
Controller PCB
Part No. POW-K91GJHA
Controls Microprocessor
Control circuit fuse 250 V 3.15 A
Remote Control Unit RCS-2HS4E
Fan & Fan Motor
Type Cross-flow
Q'ty ... Dia. and length mm 1 ... ø95 / L578
Fan motor model ... Q'ty IBH-884-020 ... 1
No. of poles ... 50Hz rpm (High) 2 ... 1,290
Nominal output W 20
Coil resistance (Ambient temp. 20°C) WHT-BRN : 201
WHT-VLT : 261
Safety devices Type Thermal fuse
Operating temp. Open °C 130
Close
Run capacitor (on the PCB Ass'y) µF 1.5
VAC 440
Flap Motor
Type Stepping motor
Model MP24GA3
Rating DC 12 V
Coil resistance (Ambient temp. 25°C) A pair of each terminal : 380 ± 7%
Heat Exch. Coil
Coil Aluminum plate fin / Copper tube
Rows 2
Fin pitch mm 1.4
Face area
m
2
0.110
DATA SUBJECT TO CHANGE WITHOUT NOTICE.