Loading...
For details, see "8-4. Removing
the electrical component box" in
Maintenance section.
Electrical
component box
P. C .Board
Panel motor
NOTE
Judgment
When a measured coil resistance deviates from any of
the listed values, replace the panel motor with new one.
Lead wire color
Coil Resistance
GRAY - GRAY 70 ohm
10-6-2. Making a Diagnosis of the Panel Motor
(1) If no abnormality was found in (1) to (3) of the previous section, then carry out diagnosis of the panel motor,
which activated the front panel.
(2) Remove the panel motor connector.
(3) Measuring coil resistance of the panel motor
Carry out measurement of the resistances as listed below:
Panel motor
Connector