11
7. FUSE PROTECTION
(保险丝保护)
To protect the power module, the Fuse will be disconnected to cut off the power supply
when the AC input current exceeds the rated current of fuse.
当输入交流电流超过保险丝的额定工作电流时,电源保险丝将断开,关闭电源供应以保护电源模块。
8. INTERNATIONAL STANDARDS(国际标准)
8.1 SAFETY(安规
Conforming
UL60950/UL60065;
EN60950-1/EN60065;
GB4943-2011/ GB8898-2011;
IEC 60950/IEC 60065.
8.2 HI-POT AND INSULATION RESISTANCE耐压性能和绝缘阻抗)
HI-POT耐压性能)
Primary to secondary(一次侧对二次侧)3000VAC, 10mA for 60s.
Insulation resistance(绝缘阻抗)
between primary and secondary(一次侧与二次侧之间)500VDC/60s, ≥50MΩ.