TROUBLE SHOOTING AND SOLUTIONS
Errors Possible causes Solutions
The appliance does not
work�
Problems with the main
electricity connection.
Ambient temperature is under
10°C.
Switch o and after 5 minutes restart.
Restart, if the ambient temperature is
higher.
Warning lamp for to less
water lights up�
Water intake disturbed
Valve is damaged.
Water pressure is too low.
Check the water intake
Check valve, if necessary, let it
exchange.
The water pressure has to be at least 1
kg/cm2.
The condenser does not
work�
Not enough water.
Ice collector container is full.
Check the water supply.
Empty the container.
The condenser works, but
no ice cubes
are produced�
Leak in the cooling system.
Condenser dusty.
Kühlsystem vom Fachmann überprüfen
lassen.
Kondensator staubfrei machen,
Lüftungsschlitze reinigen
The ice cubes do not fall
at all or only partially into
the container�
Ambient temperature or water
temperature are to low.
Valve is damaged.
Ambient temperature has to be at least
10°C and water temperature at least
7°C.
Exchange the valve.
The ice cubes always stick
together�
Storage tank is not suciently
cooled.
Often emptying.
Do not leave overnight in the storage
tank.
Control temperature.