General IconGeneral
Maximum Capacity2200 g
Readability0.01 g
DisplayLCD
Weight2.5 kg
Repeatability (Std. Dev.)0.01 g
Linearity±0.02 g
Stabilization Time (typical)2 s
Repeatability0.01 g
InterfaceRS-232
Power SupplyAC adapter
Operating Temperature10 °C to 40 °C

Summary

Warnings and Safety Precautions

Getting Started

Setting Up the Balance/Scale

Analytical Draft Shield Chamber Setup

Steps for correctly positioning and securing the draft shield chamber components.

Draft Shield and Box Connections

Connecting Electronics Box to CP225D

Specific instructions for connecting the electronics box to the CP225D model.

3-sided Draft Shield Setup

Guidance on placing and securing draft shields with a 3-sided design.

Weighing Pan and Capacity Setup

CP622 Setup

Specific setup steps for the CP622 model, including pan placement.

Rectangular Pan Setup (up to 10 kg)

Steps for setting up rectangular pans for scales with capacities up to 10 kg.

Rectangular Pan Setup (over 10 kg)

Steps for setting up rectangular pans for scales with capacities over 10 kg.

Connecting to AC Power/Safety Precautions

AC Connection for CP225D

Specific instructions for connecting the CP225D to AC power.

AC Connection for Scales up to 10 kg

Steps for connecting scales up to 10 kg to AC power.

Power, Safety and Interference

AC Connection for Scales over 10 kg

Instructions for connecting scales with capacities over 10 kg to AC power.

Connecting Peripherals and Warmup

Connecting Peripheral Devices

Instructions for safely connecting external devices like printers or PCs.

Leveling the Balance/Scale

Leveling Scales up to 10 kg

Steps for leveling scales up to 10 kg using front feet adjustment.

Leveling Scales over 10 kg

Steps for leveling scales with capacities over 10 kg.

Operating the Balance/Scale

Display and Operating Elements Overview

Describes the balance/scale's display and key operating elements.

Basic Weighing Function

Calibration and Adjustment

Internal Calibration

Internal Calibration Procedure

Step-by-step guide for internal calibration on applicable models.

External Calibration

External Calibration Procedure

Step-by-step guide for external calibration.

Configuring the Balance/Scale

Setting IDs, Time, Date, Brightness

Application Programs

Net-Total Formulation Program

Net-Total Formulation Program

Explains the Net-Total program for weighing multiple components and summing them.

Counting Program

Counting Program

Details the Counting program for determining part count based on reference sample quantity.

Reference Weighing Program

Reference Weighing Program

Guides on using a reference balance/scale for accurate counting of large parts.

Weighing in Percent Program

Weighing in Percent Program

Explains the Weighing in Percent program for proportional weight readings.

Animal Weighing/Averaging Program

Animal Weighing/Averaging Program

Covers the program for calculating average weights from multiple measurements, suitable for unstable samples.

Toggle Weight Units Program

Toggle Weight Units Program

Explains the program to switch between two different weight units for display.

Generating a Printout

ISO/GLP-compliant Printout/Record

Data Interface

Data Input Format

Error Codes

Care and Maintenance

Overview and Specifications

Competence Series/CP Series Specifications

Detailed technical specifications for various models in the Competence/CP Series.

Declaration of Conformity

Related product manuals