Do you have a question about the Sartorius CPA64-WDS and is the answer not in the manual?
Capacity | 64 g |
---|---|
Readability | 0.1 mg |
Pan Size | Ø 80 mm |
Calibration | Internal |
Repeatability | ±0.1 mg |
Linearity | ±0.2 mg |
Power Supply | AC adapter |
Read operating instructions carefully, avoid hazardous areas, only authorized personnel to open balance.
Ensure correct voltage rating for AC adapter; use caution with RS-232 cables due to potential pin assignment mismatches.
Do not expose balance to extreme temperatures, moisture, shocks, blows, or vibration.
Check for external damage immediately after unpacking. Refer to 'Care and Maintenance' for damage.
Choose a location not subject to heat, drafts, extreme vibrations, or excessive moisture.
Condition balance for 2 hours at room temperature after transfer to warmer areas to prevent condensation.
Verified balances of accuracy class II require a control seal; breaking it voids verification.
Remove adhesive tape from chamber doors and place interior draft shield and weighing pan.
Install filter pan or standard weighing pan, interior draft shield, and spacer ring as applicable.
Ensure sliding lock device on draft shield is open (right); position shield carefully on balance.
Plug the male connector on the cable into the female connector on the electronics box. Do not exchange components.
Place draft shield with cover opening in front on the right; turn clockwise until firmly in position.
Place weighing pan and gem tray (if applicable) on balance/scale.
Place the weighing pan on the balance.
Use only original Sartorius equipment; connect AC adapter to balance/electronics and then to outlet.
Select country-specific power cord, connect to AC adapter, then plug into wall outlet.
Unplug balance from AC power before connecting/disconnecting peripheral devices.
Allow specified warmup time (e.g., 4 hours for CPA2P) for exact results after power connection.
Fasten a chain or lock to the lug on the rear panel for securing the balance.
Retract rear feet; adjust front feet until bubble is centered in level indicator.
Adjust leveling feet until the air bubble is centered within the circle on the level indicator.
Description of display elements and their functions, including units, keys, symbols, and status indicators.
Use for standalone weighing or with application programs; features taring, ID assignment, and printing.
For legal metrology, calibrate/adjust at installation site after warmup; respect temperature range.
Requires steady hand; perform test measurements to adjust chamber temperature before weighing.
Circle symbol indicates power disconnection; briefly light up all segments on power-on for self-test.
Press power key to switch off balance; circle in lower left indicates standby mode.
Use filter pan with 125mm diameter; place filter on pan and close lid.
Use port on balance bottom for hanger; below-balance weighing not permitted in legal metrology.
Remove brass screw, suspend hook from hanger, install shield if necessary for drafts.
Calibration determines difference vs. true weight; adjustment corrects displayed value.
Perform internal calibration/adjustment after warmup; comply with local installation regulations.
Can be performed only when balance is tared, stable, and has no load.
External calibration/adjustment is blocked by a seal on the menu access switch for Class II.
Use menu code 1 9 3; balance applies internal weight automatically for calibration.
Configure whether calibration is followed by auto-adjustment or manual adjustment.
Automatic calibration/adjustment triggered by temperature changes or time intervals.
Configure prompt only or automatic adjustment; position cover for CPA2P-F for isoCAL.
Permitted temperature ranges are restricted for legal metrology use.
Adapt balance to individual requirements by choosing parameters from the Setup menu.
Switch balance off/on; press TARE briefly while segments are lit to open Setup menu.
Print current menu settings from various menu levels by pressing and holding the 'F' key.
Configure measurement environment for ISO/GLP records and adapt display to lighting.
Enter up to 8 characters for ID; set date and time for ISO/GLP printouts.
Set display brightness from 0 (off) to 9; note: no backlighting on some models.
F key starts/stores programs; F (hold) toggles values; CF ends programs.
All application programs selectable for legal metrology use; calculated values indicated with symbols.
Weigh components up to a defined total; store weights, automatic printout, clear memory.
Toggle between component/total weight via F key (hold); print total of individual weights.
Configure parameters for automatic printout when component is stored or for net-total data.
Determine number of parts by weighing a known quantity; minimum load equals one digit.
Press F (hold 2 sec) to set reference quantity (1, 2, 5, 10, 20, 50, 100).
F key begins piece weight determination; CF ends program or clears data.
Activates/deactivates automatic sample updating to optimize counting accuracy.
Use a reference balance for higher precision in counting large parts.
Configure CPA balance and connected scale/terminal with same interface and program settings.
Select application program and set parameters for storage, resolution, and reference scale.
Obtain weight readouts as a percentage of a reference weight; features storage and decimal place config.
Press F (hold 2 sec) to set reference percentage (1, 2, 5, 10, 20, 50, 100).
F key begins percentage calculation; CF ends program or clears data.
Select program and set parameters for storage, resolution, and decimal places for percentage calculation.
Determine weights of unstable samples by averaging subweighing operations; automatic/manual start.
Averaging starts automatically when subweights are within predefined tolerance range (calm, normal, active).
F key activates program; CF ends program or interrupts measuring.
Select program and set parameters for animal activity, start mode, and subweighing operations.
Switch display value between two weight units; configure via Setup menu code 2.1.2.
Press F key to toggle between weight unit 1 and weight unit 2.
Generate printouts with weights, values, and IDs for documentation; format to meet requirements.
Printouts generated automatically or manually; dependent or independent of stability.
Configure line format, print application parameters, ISO/GLP compliance, and auto print settings.
Displays weight or calculated value with unit.
Prints ID code (up to 6 chars) before value for identification.
Generate printout of initialization values for active application as soon as it is initialized.
Have weight readout printed automatically; includes status like display blank, underload, or overload.
Includes GLP header (date, manufacturer) and GLP footer (date, operator signature).
Configure record after calibration/adjustment or always on; set line format and data ID codes.
Press F to output header/value; press F again to include reference data; CF closes application.
Shows data like date, balance info, measurement series, counting results, and calibration details.
Details calibration/adjustment mode, weight, difference, and completion confirmation.
Connect computer/peripheral device for control and monitoring; supports RS-232C, full duplex.
Default settings for baud rate, parity, stop bits, handshake, and operating mode.
Non-verified digits shown in brackets with universal printer setting (menu code 5 5 2).
Defines characters for normal operation, special codes (overload/underload), and error codes.
Describes characters for status (H, L, C) and error codes (# # #) with positions.
Illustrates output with plus/minus sign, weight, unit, and carriage return/line feed.
ID code precedes 16-character string; defines ID character types and output format with brackets.
Codes for status (Stat), tare (T1), net weight (N, N1), and program-specific values (Comp, Qnt).
Maps error codes (E, r, #) to specific error conditions and provides meaning for ID codes.
Defines two formats for control commands (Esc, !, CR, LF / Esc, !, #, CR, LF) and command characters.
Lists command characters (K, L, M, N, O, P, R, S, T, Z) and their functions for Format 1.
Match baud rate, parity, handshake, and character format between balance and connected device.
Supports hardware handshake (CTS/DTR) and software handshake (XON, XOFF).
Controlled via XON/XOFF; XON needed to enable communication when device powers on.
Data output without print command at defined intervals; can be stopped by pressing F (depending on settings).
Details female DB25S and male connector specifications for RS-232C connections.
Warning about incorrect pin assignments on non-Sartorius cables; check chart to prevent damage.
Lists pin functions (Signal ground, Data output, CTS, DTR, +5V, +12V) for the 25-pin connector.
Lists common display errors (No segments, H, Err 01, Err 02, etc.) with their causes and solutions.
Remove weighing pan and draft shield; place in kit; secure doors with rubber band.
Remove filter pan, weighing pan, draft shield; place in kit/packaging; secure doors.
Sartorius offers service contracts; repairs by trained technicians only; caution with battery replacement.
Unplug power; clean with mild detergent and soft cloth; avoid liquid entry and aggressive agents.
Clean weighing pan and parts with damp cloth/sponge; use suitable household cleaner; rinse and dry.
Open draft shield, remove parts; use vacuum for powder, blotting paper for liquid.
Recommend periodic inspection of power supply by electrician for insulation resistance and leakage current.
Dispose of packaging and equipment according to local regulations; do not mix with household waste.
Details weighing range, readability, repeatability, linearity, temperature, and dimensions for models.
Order numbers for data printer (YDP03-0CE) and reflective remote display (YRD02Z).
Order numbers for external rechargeable battery packs (YRB05Z, YRB06Z) and carrying cases (YDB01CP, YDB02CP).
Software for data transfer and associated RS-232C adapter cables of various lengths.
Density determination kit (YDK01), antistatic weighing pan (YWP01CP), and calibration weights.
Order numbers for industrial AC adapters (ING1, ING2) and analytical draft shield chamber (YDS01CP).
Order numbers for draft shield cover (YDS02CP) and data cables (25-pin, 9-pin).
Universal remote control switch options (foot/hand switch) and T-connector.
Order numbers for weighing bowls of different volumes and dust covers for various model series.
Explains Council Directive 90/384/EEC for non-automatic weighing instruments and EC Type-Approval Certificates.
Details Sartorius services for initial verification, inspection, training, and EC verification by authorized technicians.
Validity of verification expires upon tampering; contact local office for renewal and regulations.
List of models, accuracy classes, and EC type-approval certificate numbers for instruments used in legal metrology.
Declares compliance with directives, standards, and national laws; validity depends on ID label and lack of tampering.
Provides certificate number, issuance date, validity, model types, accuracy classes, and legal basis.
Defines symbols (K, M, S, MD, T) for descriptive plates, EC verification marks, seals, metrological data, and model designation.
Illustrates placement of labels and symbols on different balance models (BC BL, BD BL, BF BL).
Shows example of a plate with model designation (T), manufacturer, model name, and CE mark.
Shows example of a verified instrument's descriptive plate (K) with temperature ranges and isoCAL status.