EasyManua.ls Logo

Sartorius ME215 - Page 144

Sartorius ME215
173 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
144
“External Keyboard” Functions
(PC-Keyboard)
Setting
Setup: Interfaces: Function “external
switch”: extra keyboard
The key codes implemented here are spe-
cific to the German keyboard layout. The
following alphanumeric characters are
implemented (some require “Shift” key):
a–z, A–Z, 0–9, <space>,
„,.\+'<>/"$@%/();=:_?*
Function keys:
PC keyboard ME/SE
F1 w key
F2 o key
F3 Softkey F6 (far left)
Cal key
F4 F5 soft key (2
nd
from left)
F5 F4 soft key (3
rd
from left)
F6 F3 soft key
(3
rd
from right)
F7 F2 soft key
(3
rd
from right)
F8 F1 soft key (far right)
F9 d key
F10
F11 r key
F12
Print r key
Return L (Enter) F1 soft key (far right)
Cursor Up F3 soft key
(3
rd
from right)
Cursor Left F4 soft key (3
rd
from left)
Cursor Down F2 soft key
(2
nd
from right)
Cursor Right F1 soft key (far right)
POS 1 (Home) F6 soft key (far left)
Cal key
Backspace c key
ESC c key
Synchronization
During data communication between the
balance and an on-line device (computer),
messages consisting of ASCII characters are
transmitted via the interface. For error-free
data communication, the parameters for
baud rate, parity, handshake mode and
character format must be the same for
both units.
You can set these parameters in the Setup
menu so that they match those of the
on-line device. You can also define
parameters in the balance to make data
output dependent on various conditions.
The conditions that can be configured are
described under each of the application
program descriptions.
If you do not plug a peripheral device into
the balance interface port, this will not
generate an error message.
Handshake
The balance interface (Sartorius Balance
Interface = SBI) has transmit and receive
buffers. You can define the handshake
parameter in the Setup menu:
Hardware handshake (CTS/DTR)
Software handshake (XON, XOFF)
Hardware Handshake
With a 4-wire interface, 1 more
character can be transmitted after CTS
(Clear to Send).
Software Handshake
The software handshake is controlled
via XON and XOFF. When a device is
switched on, XON must be transmitted
to enable any connected device to
communicate.
When the software handshake is
configured in the Setup menu, the
hardware handshake becomes active
after the software handshake.
The data transmission sequence is
as follows:
Balance ––– byte –––> Computer
(trans- ––– byte –––> (receiving
mitting ––– byte –––> device)
device) ––– byte –––>
<––– XOFF –––
––– byte –––>
––– byte –––>
(Pause)
<––– XON –––
––– byte –––>
––– byte –––>
––– byte –––>
––– byte –––>
Transmitting Device:
Once XOFF has been received, it prevents
further transmission of characters.
When XON is received, it re-enables the
transmitting device to send data.
Receiving Device:
XOFF is transmitted after the 26th
character has been stored. To prevent too
many control commands from being
received at one time, XON is not trans-
mitted until the buffer is almost empty.
Activating Data Output
You can define the data output parameter
so that output is activated either when a
print command is received or automatical-
ly and synchronously with the balance dis-
play or at defined intervals (see application
program descriptions and auto print set-
ting).
Data Output by Print Command
The print command can be transmitted
by pressing r or by a software
command (Esc P).
Automatic Data Output
In the “auto print” operating mode, data is
output to the interface port without an
extra print command. You can choose to
have data output automatically at defined
print intervals with or without the stability
parameter. Whichever parameter you select,
the data will be output as the
readouts appear on the balance display.
The display update frequency depends on
both the model of the balance and the
current operating status.
If you select the auto print setting, data
will be transmitted immediately the
moment you turn on the balance. In the
Setup menu, you can configure whether
this automatic output can be stopped and
started by pressing r.

Table of Contents

Related product manuals