SYSTEM COMPONENTS
3
2 high-load outputs with electronic fuses for “power supply output” function.
2 connectors for voice synthesisers SM-2 or CA-64 SM.
Communication bus for connection of LCD keypads; 8 LCD keypads and synoptic
table module may be connected to it.
2 buses for additional modules (expander rails), due to which 64 additional
modules may be connected to the control panel. Zone modules, output modules,
zone/output modules with power supply, partition keypads, coded locks, proximity
card readers and DALLAS chips and voice synthesisers may be connected to the
buses.
Phone communicator, provided with a DTMF detection unit, enabling reception of
commands via the telephone, monitoring, information and remote programming.
RS-232 port enabling the alarm system operation by means of a computer
(DLOAD64 installation programme), operation with a printer and the use of an
external modem.
Pulse power supply of output load 3 A, with short circuit protection, provided with
battery monitoring and discharged battery disconnection unit.
Independent real time clock with calendar, provided with its own back-up battery.
Visual signalling of operations of all outputs, battery charging circuit and
telephone communication unit.
Protection of all inputs, outputs and communication buses.
LCD keypad
Large, well-readable display 2x16 characters with permanent or temporary display
backlit after pressing the key or activated with any control panel zone.
16-key keyboard with backlit controlled as the display backlit.
2 zones with properties identical to main panel zones.
Microswitch for controlling keypad tampering.
RS-232 port allowing alarm system operation with by means of computer
(GUARD64 supervisory and user program – full monitoring of system status,
virtual keypad, facilitated management of users).
Partition keypad
12-key keypad with permanent or temporary backlit.
3 LEDs (ALARM, ARMED, FAILURE) for showing the status of partition to which
the keypad is assigned.
Microswitch for controlling keypad tampering.
Relay for control of electric catch, lock or electromagnetic interlock.
NO/NC zone for door status monitoring.
Code lock
12-key keypad with permanent or temporary backlit.
3 LEDs, showing readiness, access allowed and, additionally, system failure.
Microswitch for controlling code lock tampering.
Relay for control of electric catch, lock or electromagnetic interlock.
NO/NC zone for door status monitoring.