8 - 1 # 12 Failure Flame failure in combustion
No Symptoms and Causes Solutions Reference
Flame failure in combustion occurs when
the flame disappears during combustion
10 times consecutively.
-
Check gas supply pressure
LNG: 100 ~ 250 mmAq.,
LPG: 230 ~ 330
mmAq
- Check whether LPG is empty when gas
pressure is low and if it is replace with a new
full container.
<Fig. 1>
- In cold seasons, the gas container may not
supply gas normally. Warm up the container
first.
- LPG hose may be too long (more than 3 m) or
have fold down. Replace the hose or shorten
it.
- The gas meter may be defective. Contact the
gas company for replacement.
<Fig. 2>
1 Gas supply pressure is not right.
- Gas initial supply pressure of 200 mmAq may
fall down under 100 mmAq after combustion.
In that case contact the gas company.