EasyManua.ls Logo

Saturn KDB - 301 GOM - Wiring FR-5 Thermostat

Saturn KDB - 301 GOM
106 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
KDB-GOM
Series
- 44 -
4. Mount the back plate to the wall using either of the above techniques(depending on the construction of the wall).
Recheck all connections both inside the unit and at the thermostat. Be careful not to pinch the control wires. Pinched
or shorted wires will prevent the system from operating. Do not over tighten wire nut connecting wires together.
5. Use countersunk type screws.
CAREFULLY TIGHTEN THE 2 SCREWS WHEN CONNECTING THE WIRES. DO NOT APPLY EXCESSIVE
FORCE.
IF THE INSULATION OF THE WIRES IS DAMAGED OR IF THE TERMINALS ARE ON POOR CONTACT, THE
ROOM THERMOSTAT WILL NOT WORK PROPERLY. BE CAREFUL TO PROTECT THE INSULATION OF THE
WIRES.
[Wiring FR-5 Thermostat]
DC 20V
FR-5 Thermostat
2 Orange Wires
Main
Controller
AC 220V, 50/60Hz
Grounded Power Supply
to Boiler
Boiler

Table of Contents

Related product manuals