Ensure the system is full and at suitable
operation pressures. Fill and thoroughly
purge all connected pipework.
21
Reset the boiler by turning the power off and on.
Close the oil pump vent, press the power button
again and the boiler will ignite. If the boiler fails to
fire after 3 successive attempts contact the Saturn
technical helpline on 1890 929 112.
Preparation and checking before start-up
The boiler must always be correctly
grounded according to relevant local regulations.
Connect the boiler to the main 220v supply
and press the power button. The “RUN”
light should show after a short period.
Volt free boiler call (Orange cable)
Warning: Connecting power to this cable will
damage the boiler control panel.
Full wiring instructions on pages 36-41