EasyManua.ls Logo

Saunier Duval ThemaClassicPlus F 24 E - User Manual

Saunier Duval ThemaClassicPlus F 24 E
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
MEMO
Question and Answer IconNeed help?

Do you have a question about the Saunier Duval ThemaClassicPlus F 24 E and is the answer not in the manual?

Summary

Descriptions ThemaClassicPlus F

Wiring diagram ThemaClassicPlus F

Characteristics ThemaClassicPlus

Heating characteristics

Details heating performance parameters like temperature, power, and flow rate.

Hot water characteristics

Lists specifications for domestic hot water production, including temperature and pressure.

Gas characteristics

Provides gas pressure and flow rate data for different gas types like natural gas and propane.

User interface ThemaClassicPlus

How to display data menu?

Explains access to a hidden menu for installers and after-sales service via codes.

Data menu ThemaClassicPlus

Gas mechanism adjustment

Setting reduced power: via point 24

Guides on adjusting burner pressure for reduced power output, locking at reduced pressure.

Setting maximum power: via point 25

Guides on adjusting burner pressure for maximum power output, locking at maximum power.

Details data menu ThemaClassicPlus

Aeraulic configuration

Defines fan speed adjustment based on flue length and boiler model for optimal performance.

Outdoor sensor

Explains outdoor sensor setup via menu points 4, 6, and 7 for temperature compensation.

Failure codes list ThemaClassicPlus

Diagnostic aid ThemaClassicPlus

Air flow safety (Code 02)

Explains checks for air flow safety issues and symbol display on the unit.

No ignition (Code 04)

Details checks for ignition failures, voltage requirements, and electrode connections.

Overheating loop (Code 05)

Lists checks for overheating loop faults like pump, thermostat, or electrical connections.

Diagnostic aid ThemaClassicPlus (Continued)

Heating sensor loop (Code 06)

Details checks for heating sensor loop faults, including open or short circuits.

Pressure sensor loop (Code 09)

Explains checks for pressure sensor loop faults, sensor insulation, and connections.

Lack of water (Code 21)

Provides checks for lack of water in the primary circuit, recommending water topping-up.

Too much water pressure (Code 22)

Lists checks for excessive water pressure issues, including expansion vessel and sensors.

Hydraulic characteristics ThemaClassicPlus

Saunier Duval ThemaClassicPlus F 24 E Specifications

General IconGeneral
Fuel TypeNatural Gas
Output24 kW
DHW Output24 kW
Maximum working pressure3 bar
Flue diameter60/100 mm
TypeCondensing
MountingWall-mounted

Related product manuals