Monarch Fixed Ceiling Lift Owner’s Manual Part No. 001108-EN, 21-m09-2017
Dealer Maintenance Schedule
Perform the checks/actions listed in the Operator Maintenance Schedule as
well as those listed in the table below.
To avoid potential injury, use ONLY Savaria parts when
replacing parts.
To prevent the person from falling (or objects from
falling) that may cause injuries to the person, the
operator or other persons, always reinstall the track end
stops if they were removed for servicing. Note that the
recommended tightening torque is 20 N-m (15 lb-ft).
Figure 21
Dealer Check/Action Frequency
Check the lift casing for any damage Every year
Check the lift transmission Every year
Check the lift connecting joints Every year
Check that the emergency brake is turning freely Every year
Check that all emergency devices are working properly Every year
Perform a load test on the lift and track system with the Safe
Working Load
Every year
Replace the lift strap Every 2 years
Lubricate the roller and the spool shaft Every 2 years
Lubricate the transmission spool gear Every 2 years