SAFETy
REGULATION
• Do not let persons, children included, with reduced physical
sensory, reduced mental funcons or lack of experience and
knowledge use the appliance. They must have supervision or
instrucon for the operaon of the appliance by a person who is
responsible for their safety.
• Do not let children play with the appliance.
POWER SUPPLY
• An AC power adapter is required to be connected to a wall outlet.
Be sure only to use an adapter with the appropriate AC voltage
rang to prevent component damage. A DC 12V switching power
output and 1A adapter is provided and generally used to power
the device.
• In addion to the adapter, there is a rechargeable baery inside
the device that serves as a back-up in case of a power failure.
• During normal operaon, the AC power adapter is used to supply
power to the Control Panel and at the same me recharge the
baery. It takes approximately 48 hours to fully charge the
baery. When the AC power adapter is removed, the system will
begin to detect baery condion automacally.
• If the AC Power Failure lasts for 15 seconds, the Power LED
indicator will go o. Aer the AC power failure situaon lasts for
15 minutes, an AC power failure message will be transmied via
SMS to alert the user.
• When the AC power has been restored for 15 seconds, the Power
LED indicator resumes lighng. Aer the AC power is restored
and lasts for 15 minutes, an AC power restored message, will be
sent to inform the user.
• When Low Baery status is detected and lasts for 15 seconds,
the Baery LED will begin to ash. If Low Baery status lasts for 3
minutes, a Low Baery message will be sent via SMS to alert the
user.
• When the baery voltage is restored for 15 seconds, the Baery
LED turns on again. If the baery voltage restoraon lasts for 12
hours, a Baery Restore Message will be sent to inform the user.
• If the Baery is disconnected or switched o for 15 seconds, the
Baery LED indicator will go o. If the Baery is disconnected or
switched o for 3 minutes, a Baery Disconnected message will
be sent via SMS to alert the user.
• When the Baery connecon is restored or switched on for 15
seconds, the Baery LED indicator will turn on again. Aer the
Baery restoraon lasts for or 3 minutes, a Baery Disconnected
Restore Message will be sent to inform the user.
ENGLISH
10