EasyManuals Logo

Schaudt DT 201 B User Manual

Schaudt DT 201 B
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #21 background imageLoading...
Page #21 background image
SDT-0018-02EN Situation: 18.07.2005 21
Instruction Manual Control and Switch Panel DT 201 B
9 Technical faults, possible causes and remedies
If you are unable to solve a fault using the following tables, please contact our
customer service address.
If this is not possible, e.g. if you are abroad, you can have the control and
switch panel repaired at a specialist workshop.
Inexpert repairs invalidate the guarantee for the control and switch panel and
Schaudt GmbH takes no liability for any resulting damage.
Fault Possible cause Remedy
12 V power supply does
not work
12 V main switch turned off Switch on the 12 V main
switch
No voltage in living area
battery
Living area battery is
discharged
Charge the living area bat-
tery immediately
W
If the living area
battery is totally
discharged for a
lengthy period, it
will be irrepara-
bly damaged
The battery can be dis-
charged by inactive con-
sumers such as the frost
protection valve in the
heater system
Fully charge the living area
battery before you shut
down the motorhome for
any lengthy period
Step alarm even though
the step is retracted
Defective sensors or miss-
ing D+ signal
Switch off the acoustic
warning signal (see the
section 5.7) and contact
customer service

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Schaudt DT 201 B and is the answer not in the manual?

Schaudt DT 201 B Specifications

General IconGeneral
BrandSchaudt
ModelDT 201 B
CategoryControl Unit
LanguageEnglish