811.550 BA / EN Edition: 21.08.2008 11
Instruction Manual Electrobloc EBL 101
Living area battery is not
charged during mobile
operation (battery voltage
below 13.0 V)
Defective alternator Have the alternator
checked
No voltage at D+ input Have the fuse and wiring
checked
Defective Electrobloc Call customer service
The living area battery is
overloaded during mobile
operation (battery voltage
constantly above 14.3 V)
Defective alternator Have the alternator
checked
The refrigerator does not
work during mobile opera-
tion
No power supply to the
refrigerator
Have the fuse and wiring
checked
Defective Electrobloc Call customer service
Defective refrigerator Have the refrigerator
checked
Solar charger does not
work (power supply and
engine are off)
Solar charge regulator not
plugged in
Plug in the solar charge
regulator
Defective fuse or wiring Have the fuse and wiring
checked
Defective solar charge reg-
ulator
Have the solar charge reg-
ulator checked
12 V power supply in the
living area does not work
12 V main switch for the liv-
ing area battery is
switched off
Switch on the 12 V main
switch for the living area
battery
Battery cut-off switch is
switched off
Switch on the battery cut-
off switch
Defective fuse or wiring Have the fuse and wiring
checked
Defective Electrobloc Call customer service
Fault Possible cause Remedy
If the device becomes too hot due to excessive ambient temperature or
lack of ventilation, the charging current is automatically reduced. However,
always prevent the device from overheating.
If the automatic shutdown mechanism of the battery monitor is triggered,
fully charge up the living area battery.