www.scheppach.com
26
|
GB
• The laser may not be replaced with a dierent type
of laser.
• Repairs of the laser may only be carried out by the
laser manufacturer or an authorised representative.
• Labelling and placement of warning stickers, see
g. 8 and 9.
m WARNING! This electric tool generates an electro-
magnetic eld during operation. This eld can impair
active or passive medical implants under certain con-
ditions. In order to prevent the risk of serious or deadly
injuries, we recommend that persons with medical im-
plants consult with their physician and the manufactur-
er of the medical implant prior to operating the electric
tool.
Residual risks
Even if you use this electric power tool in accord-
ance with instructions, certain residual risks can-
not be eliminated. The following hazards may
arise in connection with the equipment’s con-
struction and layout:
• Lung damage if suitable dust protection mask is not
worn.
• Hearing damage if suitable hearing protection is not
worn.
• Damage to health resulting from hand/arm vibration
if the device is used over an extended period of time
or if it is not properly operated and maintained.
6. Technical data
Nominal input voltage
230-240 V∼/50 Hz
Power rating
350 W (S1)
500 W (S6 40%)
Motor speed 1450 min
-1
Output speed
600 min
-1
900 min
-1
1300 min
-1
1800 min
-1
2650 min
-1
Drill chuck mount B16
Drill chuck 1,5 - 13 mm
Dimensions of drill table 160 x 160 mm
Angle adjustment of table 45°/0°/45°
Drill depth 50 mm
Pillar diameter 46 mm
e) The drill must be turning before it makes con-
tact with the workpiece. Otherwise, the drill bit
can catch in the workpiece and this can result in
an unexpected movement of the workpiece and
cause injuries.
f) If the drill becomes jammed, stop pressing
downwards and switch the electrical tool o.
Investigate and rectify the cause of the jam-
ming. Jamming can result in an unexpected move-
ment of the workpiece and can result in serious
injuries.
g) Avoid long pieces of drill swarf by interrupting
the downward pressure at regular intervals.
Sharp metal swarf can become tangled and lead
to injuries.
h) Never remove drilling debris from the drilling
area whilst the electrical tool is running. To
remove swarf, move the drill away from the
workpiece, switch o the electrical tool and
wait until the drill has come to a standstill. Use
an aid such as a brush or a hook to remove the
swarf. Contact with rotating parts or drilling debris
can cause injuries.
i) The permissible rotational speed for drill bits
with a rated speed must be at least as high as
the highest speed cited on the electrical tool.
Accessories that rotate faster than permitted can
break and y o at high speed.
Attention: Laser radiation
Do not look into the beam
Laser class 2
Protect yourself and you environment from acci-
dents using suitable precautionary measures!
• Do not look directly into the laser beam with un-
protected eyes.
• Never look into the path of the beam.
• Never point the laser beam towards reecting sur-
faces and persons or animals. Even a laser beam
with a low output can cause damage to the eyes.
• Caution - methods other than those specied here
can result in dangerous radiation exposure.
• Never open the laser module. Unexpected exposure
to the beam can occur.