Sound power level L
WA
88.3 dB
Guaranteed sound power level
L
WA
92 dB
Uncertainty K
WA
3 dB
Vibration parameters
Vibration
a
h
2.089 m/s
2
Uncertainty K 1.5 m/s²
The specied total vibration value and the specied
noise emission value have been measured in accord-
ance with a standardised test procedure and can be
used to compare one power tool with another.
The total noise emission values specied and the total
vibration emission values specied can also be used
for an initial estimation of the load.
m WARNING! The noise emission values and vi-
bration emission value can var y from the specied
values during the actual use of the power tool, de-
pending on the type and the manner in which the
electric tool is used, and in particular the type of
workpiece being processed.
Try to keep the stress as low as possible. Exemplary
measures: the limitation of working hours. In doing so,
all parts of the operating cycle
must be taken into account (such as times in which
the electric tool is switched o󰀨 or times in which it is
switched on, but is not running under a load).
8. Unpacking
Open the packaging and carefully remove the product.
Remove the packaging material, as well as the pack-
aging and transport safety devices (if present).
Check whether the scope of delivery is complete.
Check the product and accessory parts for transport
damage. In the event of complaints the carrier must
be informed immediately. Later claims will not be
recognised.
If possible, keep the packaging until the expiry of the
warranty period.
Familiarise yourself with the product by means of the
operating manual before using for the rst time.
With accessories as well as wearing parts and re-
placement parts use only original parts. Spare parts
can be obtained from your specialist dealer.
Before performing setting or maintenance work, re-
lease the start button and pull out the power plug.
Warning! This power tool generates an electromagnet-
ic eld during operation. This eld can impair active or
passive medical implants under certain circumstances.
In order to prevent the risk of serious or deadly injuries,
we recommend that persons with medical implants
consult with their physician and the manufacturer of
the medical implant prior to operating the power tool.
7. Technical data
AC motor 230 V~
Power 1600 W
Length of mains connection
cable
5 m
Length of high-pressure hose 5 m
Weight 7.2 kg
Protection class II
Protection category IPX5
Design pressure / working
pressure (p)
9 MPa / 90 bar
Max. permissible pressure
(p max)
13.5 Mpa / 135
bar
Max. supply pressure (p max) 1.2 Mpa / 12 bar
Max. supply temperature (T
in max)
50°C
Rated ow rate (Q) 6 l/min
Max. ow rate (Qmax) 7 l/min
Subject to technical changes!
Noise and vibration
m WARNING! Noise can have serious e󰀨ects on your
health. If the machine noise exceeds 85 dB, please
wear suitable hearing protection for you and persons
in the vicinity.
The noise and vibration values have been determined
in accordance with EN 60335-2-79.
Noise data
Sound pressure level L
pA
74.6 dB
Uncertainty K
pA
3 dB