P517-381
Installation Preparation
Door preparation:
For door preparation use the template included in the package with the
lock. For additional information, visit the website www.allegion.com/us.
IMPORTANT – LOCK TIMING
L LOCK TIMING is the positioning and adjustment of internal lock
components.
L Functions not listed below do not require timing.
THE FOLLOWING LOCKING FUNCTIONS MUST BE TIMED:
ND60 (including XN12-001)
ND72 (including XN12-002 and XN12-003)
ND70 ND73 ND75 ND93 ND94
ND95 ND97 ND25x70 ND70x80
See ND‑Series Timing Guide (P517‑432) in package.
For additional assistance, contact Product Support at
1-877-671-7011.
1 Install latch
The bevel must face toward the door stop.
Actual Size
ND‑Series
Installation Instructions
ND53 Function shown
Outside
Lever
Inside Lever
Rose
Latch
Strike
Mounting
Screws (2)
Inside Spring
Cage
Optional Spacer
for 1³⁄₈” Door (2)
Anti‑Rotation
Plate
Adjustment
Plate
Chassis
Cylinder Options
Full Size IC (FSIC)
Small Format (SFIC)
Standard Cylinder
Pin wrench

Other manuals for Schlage ND75

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Schlage ND75 and is the answer not in the manual?

Schlage ND75 Specifications

General IconGeneral
TypeDeadbolt
SeriesND
FunctionClassroom
Grade1
KeywaySchlage C
MaterialSteel
Backset2-3/4"
Door Thickness1-3/4"
HandingNon-Handed
Latchbolt Throw1"
FinishSatin Chrome
ANSI Grade1