EasyManua.ls Logo

Schlage ND Series User Manual

Schlage ND Series
4 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Manuals+
User Manuals Simplified.
SCHLAGE ND-Series Electrified Locks Instructions
Home » Schlage » SCHLAGE ND-Series Electrified Locks Instructions
SCHLAGE ND-Series Electrified Locks Instructions
Contents [ hide
1 ND-Series Electrified Lock
1.1 For standard installation, see full instruction
sheet.
2 Troubleshooting:
3 Request-to-Exit (RX) Lock
4 Allegion Connect
5 File Downloads
6 References
7 Related Manuals
ND-Series Electrified Lock
For standard installation, see full instruction sheet.
Select the appropriate mode for the installation using the mode select switch located on the chassis. Note: When mode is
switched (from EL to EU or EU to EL) the lock requires a complete lock/unlock power cycle to synchronize to the proper mode.
EL, electrically locked (fail safe):
Outside knob/lever or both outside and inside knobs/levers (depending on function) will lock when power is applied. In the event of power
failure, the opening will be unlocked.
EU, electrically unlocked (fail secure):
Outside knob/lever or both outside and inside knobs/levers (depending on function) will unlock when power is applied. In the event of
power failure, the opening will be locked.

Other manuals for Schlage ND Series

Question and Answer IconNeed help?

Do you have a question about the Schlage ND Series and is the answer not in the manual?

Schlage ND Series Specifications

General IconGeneral
Door Thickness1-3/4" to 2-1/4"
Strike Plate IncludedYes
FunctionClassroom, Storeroom
Backset2-3/4"
Latch1/2" throw latch
StrikeANSI 1-1/4" x 4-7/8"
KeywaySchlage C
CertificationANSI/BHMA Grade 1
MaterialBrass
ApplicationsCommercial, Institutional
HandingNon-Handed (field reversible)
Latch TypeDeadlatch
Warranty3-year limited warranty
FinishOil Rubbed Bronze

Summary

ND-Series Electrified Lock Modes

EL, Electrically Locked (Fail Safe)

Defines the fail-safe mode where the lock locks when power is applied and unlocks on power failure.

EU, Electrically Unlocked (Fail Secure)

Defines the fail-secure mode where the lock unlocks when power is applied and locks on power failure.

Electrical Requirements

Troubleshooting

Request-to-Exit (RX) Lock

Allegion Connect System

Wire Color and Function

Details wire assignments for color, function, and pin configuration for Allegion Connect system.