EasyManua.ls Logo

schmersal AZM 200 - User Manual

schmersal AZM 200
10 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
AZM 200
Operating instructions
Solenoid interlock
EN
1
1. About this document
1.1 Function
This operating instructions manual provides all the information you
need for the mounting, set-up and commissioning to ensure the safe
operation and disassembly of the safety switchgear. The operating
instructions must be available in a legible condition and a complete
version in the vicinity of the device.
1.2 Target group: authorised qualified personnel
All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only.
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation.
The machine builder must carefully select the harmonised standards
to be complied with as well as other technical specifications for the
selection, mounting and integration of the components.
1.3 Explanation of the symbols used
Information, hint, note:
This symbol is used for identifying useful additional information.
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine.
1.4 Appropriate use
The products described in these operating instructions are developed to
execute safety-related functions as part of an entire plant or machine. It
is the responsibility of the manufacturer of a machine or plant to ensure
the correct functionality of the entire machine or plant.
The safety switchgear must be exclusively used in accordance with
the versions listed below or for the applications authorised by the
manufacturer. Detailed information regarding the range of applications
can be found in the chapter "Product description".
1.5 General safety instructions
The user must observe the safety instructions in this operating
instructions manual, the country-specific installation standards as well
as all prevailing safety regulations and accident prevention rules.
Further technical information can be found in the Schmersal
catalogues or in the online catalogue on the Internet:
www.schmersal.net.
The information contained in this operating instructions manual is
provided without liability and is subject to technical modifications.
Content
1 About this document
1.1 Function.............................................1
1.2 Target group: authorised qualied personnel ................1
1.3 Explanation of the symbols used..........................1
1.4 Appropriate use.......................................1
1.5 General safety instructions ..............................1
1.6 Warning about misuse..................................2
1.7 Exclusion of liability ....................................2
2 Product description
2.1 Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2 Special versions ......................................2
2.3 Comprehensive quality insurance to 2006/42/EC .............2
2.4 Destination and use....................................2
2.5 Technical data ........................................2
2.6 Safety classication....................................3
3 Mounting
3.1 General mounting instructions............................3
3.2 Manual release .......................................4
3.3 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
4 Electrical connection
4.1 General information for electrical connection ................4
5 Operating principle and diagnostic functions
5.1 Magnet control........................................4
5.2 Mode of operation of the safety outputs ....................4
6 Diagnostic functions
6.1 Diagnostic LED's ......................................5
6.2 Solenoid interlock with conventional diagnostic output .........5
6.3 Solenoid interlock with serial diagnostic function .............6
7 Set-up and maintenance
7.1 Functional testing .....................................7
7.2 Maintenance .........................................7
8 Disassembly and disposal
8.1 Disassembly .........................................7
8.2 Disposal.............................................7
9 Appendix
9.1 Wiring examples ......................................8
9.2 Wiring conguration and accessories . . . . . . . . . . . . . . . . . . . . . .9
10 EU Declaration of conformity
x.000 / 05.2017 / v.A. - 101178802-EN / R / 2017-03-28 / AE-Nr. 7307
EN
Operating instructions. . . . . . . . . . . .pages 1 to 10
Original
Question and Answer IconNeed help?

Do you have a question about the schmersal AZM 200 and is the answer not in the manual?

Summary

About This Document

Function

Explains the purpose of the operating instructions manual.

Target Group

Specifies that only trained personnel should perform operations.

Symbols Used

Describes symbols for information, caution, and warning notices.

Appropriate Use

Defines the intended application of the safety switchgear in machines.

General Safety Instructions

Advises adherence to country-specific standards and safety regulations.

Product Description

Ordering Code

Lists various options and their meanings for product ordering.

Special Versions

Notes that specifications apply to unlisted special versions if they match the standard.

Quality Assurance

States Schmersal's certification and availability of prototype test certificates.

Destination and Use

Explains the application in safety circuits for monitoring movable guards.

Technical Data

Provides technical specifications like standards, materials, and electrical data.

Mounting

General Mounting Instructions

Guides on fitting the interlock, avoiding use as an end stop.

Manual Release

Explains unlocking the interlock in a de-energised state using a triangular key.

Dimensions

Shows the physical dimensions of the solenoid interlock in mm.

Electrical Connection

General Information

Advises on connection by authorised personnel in a de-energised state.

Operating Principle

Magnet Control

Explains how the IN signal controls locking for power-to-unlock/lock versions.

Safety Outputs Operation

Describes how safety outputs behave when the guard is opened or interlock is not engaged.

Diagnostic Functions

Diagnostic LEDs

Explains the function of the green, yellow, and red LEDs for status indication.

Conventional Diagnostic Output

Details the diagnostic output signals for 1P2P and 1P2PW variants.

Serial Diagnostic Function

Explains the serial diagnostic output and its evaluation via PLC.

Set-up and Maintenance

Functional Testing

Lists essential checks for the safety function before and during use.

Maintenance

Recommends regular visual inspections and functional tests for upkeep.

Disassembly and Disposal

Disassembly

Instructs to disassemble the switchgear only when de-energised.

Disposal

Advises on proper disposal in accordance with national regulations.

Appendix

Wiring Examples

Provides schematic diagrams for series-wiring with conventional and serial diagnostics.

Wiring Configuration and Accessories

Details pin configurations, colour codes, and available cables/connectors.

EU Declaration of Conformity

Summary

About This Document

Function

Explains the purpose of the operating instructions manual.

Target Group

Specifies that only trained personnel should perform operations.

Symbols Used

Describes symbols for information, caution, and warning notices.

Appropriate Use

Defines the intended application of the safety switchgear in machines.

General Safety Instructions

Advises adherence to country-specific standards and safety regulations.

Product Description

Ordering Code

Lists various options and their meanings for product ordering.

Special Versions

Notes that specifications apply to unlisted special versions if they match the standard.

Quality Assurance

States Schmersal's certification and availability of prototype test certificates.

Destination and Use

Explains the application in safety circuits for monitoring movable guards.

Technical Data

Provides technical specifications like standards, materials, and electrical data.

Mounting

General Mounting Instructions

Guides on fitting the interlock, avoiding use as an end stop.

Manual Release

Explains unlocking the interlock in a de-energised state using a triangular key.

Dimensions

Shows the physical dimensions of the solenoid interlock in mm.

Electrical Connection

General Information

Advises on connection by authorised personnel in a de-energised state.

Operating Principle

Magnet Control

Explains how the IN signal controls locking for power-to-unlock/lock versions.

Safety Outputs Operation

Describes how safety outputs behave when the guard is opened or interlock is not engaged.

Diagnostic Functions

Diagnostic LEDs

Explains the function of the green, yellow, and red LEDs for status indication.

Conventional Diagnostic Output

Details the diagnostic output signals for 1P2P and 1P2PW variants.

Serial Diagnostic Function

Explains the serial diagnostic output and its evaluation via PLC.

Set-up and Maintenance

Functional Testing

Lists essential checks for the safety function before and during use.

Maintenance

Recommends regular visual inspections and functional tests for upkeep.

Disassembly and Disposal

Disassembly

Instructs to disassemble the switchgear only when de-energised.

Disposal

Advises on proper disposal in accordance with national regulations.

Appendix

Wiring Examples

Provides schematic diagrams for series-wiring with conventional and serial diagnostics.

Wiring Configuration and Accessories

Details pin configurations, colour codes, and available cables/connectors.

EU Declaration of Conformity

schmersal AZM 200 Specifications

General IconGeneral
Product nameAZM 200
Principle of operationMagnetic
Rated voltage24 V DC
Locking force Fmax2000 N
Enclosure materialPlastic
Protection classIP67
Operating temperature-25 °C to +70 °C
Switching distance8 mm
Operating voltage24 V DC
Safety categoryCategory 4
MaterialPlastic
ConnectionConnector
Connection typeM12 connector
StandardsEN ISO 13849-1
Housing materialZinc die-cast

Related product manuals