2.2 UI-Table (User Interface)
This setting allows the adjustment of the control system to the various models.
IMPORTANT: If you change the UI table and save these changes, the machine is automatically
reset to default settings.
2.3 Heating variant
Electric Settings for all domestic appliances.
Steam indirect This setting has no influence on any domestic appliances.
Hot water This setting has no influence on any domestic appliances.
2.4 Self-cleaning
Yes Solenoid installed for cleaning the evaporator.
No No Y-valve and no solenoid. Condensate is either pumped into the condensate
drawer or into the drainage hose.
2.5 Y-valve
Yes Y-valve installed. The condensate is either pumped up into the condensate
container (cleaning) or to the outside into the drainage hose.
No No Y-valve. Condensate is always pumped into the drainage hose.
2.6 Welcome text
Neutral Without welcome text and logo
Schulthess ... The selected company name always appears on the display on turning on the
machine.
2.7 Payment options
These functions are described in the CRM14 Payment System guide.
Without No payment system installed
Card CRM14 (Cash Reader Module) installed
Token Unit with integrated token function
Coin Unit with integrated coin function
RS-485 Module RS485 installed
2.8 Lock settings
Yes The settings are blocked for the customer, apart from the Language
(temporary), Time and Date settings (these are never blocked).