deltaSchwank
Radiant Tube Heater
with pneumatic gas-/air ratio control
310U / 320U / 625U / 635U / 950U / 1260U
modulating operation
single heater and flue gas collection system [herringbone] type F
Technical
Manual
Technical Instructions
Operating Instructions
Legal Requirements
Assembly Instructions
Installation Instructions
Commissioning
Service Guide
0085CS0487
Version 003 deltaSchwank 16/19 INT
Technical s
p
ecification sub
j
ect to chan
g
e
Question and Answer IconNeed help?

Do you have a question about the Schwank deltaSchwank Series and is the answer not in the manual?

Summary

1 Introduction and Safety Overview

Safety Introduction and Notes

General safety information and warnings for safe operation of the heater.

2 Your Safety

Safety for Electrical Equipment

Precautions and warnings for safe handling of electrical components.

4 Planning and Installation Requirements

Mounting Warnings and Precautions

Important warnings regarding mounting, thermal expansion, and fixing elements.

6 Operation

Startup, Shutdown, and Fault Handling

Procedures for operating, stopping, and managing faults.

7 Technical Specification

Detailed Technical Data Table

Comprehensive table of technical data and performance values.

8 Operating Description

Fault Diagnosis and Resetting

How to handle faults and reset the system.

9 Assembly Instructions

10 Installation Instructions

Gas Safety and Installation Warnings

Critical safety warnings for gas pipe installation.

MODBUS Communication and Control

Details on MODBUS setup and operation.

11 Commissioning Instructions

Pre-Commissioning Checks and Safety

Essential checks and safety precautions before commissioning.

Parameter Configuration for IC 4000;1

Setting parameters on the burner control unit.

Adjusting Heat Load and Modulating Range

Steps for setting the nominal heat load and modulating range.

Setting Negative Pressure Levels

Adjusting negative pressure for proper exhaust evacuation.

12 Service Guide and Troubleshooting

Regular Maintenance and Annual Checks

Requirements for routine maintenance and annual inspections.

Error Codes and Their Meanings

List and explanation of error codes for the burner control unit.

Troubleshooting Common Error Causes

Identifying and resolving typical error conditions.

Schwank deltaSchwank Series Specifications

General IconGeneral
Fuel TypeNatural Gas or Propane
Reflector MaterialAluminum
EfficiencyUp to 93%
Mounting TypeCeiling or Wall Mount
Ignition TypeElectronic
Thermostat CompatibilityYes
DimensionsVaries by model
WeightVaries by model
TypeInfrared Heater
BTU Range50, 000 - 200, 000 BTU/h
IgnitionDirect Spark
Coverage AreaVaries by model
VentilationVented
Heating Capacity15, 000 - 60, 000 BTU/hr