    What to do if my Schwank infraSchwank D 15U burner does not start?
    • J
      James TaylorAug 12, 2025
      If the burner on your Schwank Heater doesn't start, there could be several reasons: * There might be no gas supply. In this case, check the pre- and nozzle pressure. * There may be a fault in the electrical supply. * The thermostat might be set to "OFF". Ensure the thermostat is set to "ON". * The connection of the ignition- and ionization electrode could be wrong; ensure that it is correctly connected. * The differential pressure switch may be defective or out of order. Replace or repair the differential pressure switch.
  • B
    Brandon SheaAug 19, 2025
    What to do if Schwank Heater control goes into fault position during operation?
    • R
      Ronald MyersAug 20, 2025
      If your Schwank Heater control goes into a fault position during operation, it could be due to: * The flame being off, so ensure the flame is on. * The contact of the differential pressure switch opens, so check the differential pressure switch. * A poor flame signal, so improve the flame signal.
  • J
    Johnny WillisAug 27, 2025
    Why does my Schwank Heater control go into fault position during the safety time?
    • M
      Michelle GarciaAug 27, 2025
      If the control of your Schwank Heater goes into the fault position during the safety time, it could be due to: * No flame (no ignition, valve doesn't open, no gas). Check the ignition, valve operation, and gas flow. * No or poor flame signal (flame does not stick, bad insulation of the flame detector, no contact between burner and earth connection). Resolve the flame signal issue. * Wrong polarity, so check the polarity.
  • K
    Kimberly StewartSep 2, 2025
    How to resolve fault position during pre-purge period in Schwank infraSchwank D 15U Heater?
    • T
      Trevor YangSep 2, 2025
      If your Schwank Heater control goes into a fault position during the pre-purge period, this could be due to: * A flame signal wrongfully caused by an electrical defect of control, so address the electrical defect of control. * Insufficient pressure differential, so resolve the pressure differential issue.