Sequence of Operation - Harvest
• Hot gas valve opens
• Pump and Fan motor stop
• Inlet water valve opens and refills the reservoir
– Fill time varies with evaporator temperature
• Timed during a power restart or in clean cycle
• Harvest continues
– When the evaporator temperature warms to a preset
point – 50, a 20 second (default) timer starts