Sequence of Operation - Harvest
Hot gas valve opens
Pump and Fan motor stop
Inlet water valve opens and refills the reservoir
Fill time varies with evaporator temperature
Timed during a power restart or in clean cycle
Harvest continues
When the evaporator temperature warms to a preset
point – 50, a 20 second (default) timer starts
When the time expires, harvest ends