EasyManuals Logo

SCOTT RIT-PAK III User Manual

SCOTT RIT-PAK III
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #35 background imageLoading...
Page #35 background image
Page35of36
P/N 595225-01 Rev C 4/12
WARNING
DO NOT APPLY ANY MARKINGS OR
LABELS THAT DAMAGE OR INTERFERE
WITH THE OPERATION OF THE EQUIPMENT.
ANY USER APPLIED MARKINGS THAT
INTERFERE WITH THE OPERATION OF
THE EQUIPMENT MAY CAUSE A FAILURE
OF THE EQUIPMENT AND MAY RESULT IN
SERIOUS INJURY OR DEATH.
WARNING
APPLYING ANY MARKINGS OR LABELS
THAT DAMAGE OR OBSCURE THE
EXISTING LABELING MAY INTERFERE
WITH PROPER IDENTIFICATION OF
ASSEMBLIES. IMPROPER IDENTIFICATION
OF ASSEMBLIES MAY RESULT IN ERRORS
IN MAINTENANCE OR OPERATION
CAUSING FAILURE OF THE EQUIPMENT
WHICH MAY RESULT IN SERIOUS INJURY
OR DEATH.
EQUIPMENT MARKINGS
Do not alter or cover over any labels on the SCOTT RIT-PAK III portable air
supply or air supply cylinder and valve assembly. If user applied identification
markings are added to the SCOTT RIT-PAK III portable air supply or air supply
cylinder and valve assembly, do not obscure any labels supplied on the SCOTT
RIT-PAK III portable air supply or air supply cylinder and valve assembly. Any user
applied markings must be applied in a manner that will not weaken or damage
any components of the SCOTT RIT-PAK III portable air supply or the air supply
cylinder and valve assembly, will not interfere with the proper function of these
assemblies, and will not add flammable materials to these assemblies.
TECHNICAL SPECIFICATIONS
The Pressure Reducer Assembly that is provided with the SCOTT RIT-PAK III
portable air supply is equipped with a relief valve. If air is heard or felt coming
fromthereliefvalve,DONOTUSETHEASSEMBLY.Removetheequipmentfrom
service and tag for repair by authorized personnel.
A properly functioning Reducer Assembly connected to a fully charged cylinder
(appropriate for the operating pressure of the unit) will have output pressure of
approximately70psig to 100psigwithno flow andaminimum outlet pressure
of55psigwithaflowofapproximately400litersperminute.
PERIODIC TESTING
SCOTT recommends that the SCOTT RIT-PAK III portable air supply be checked,
both visually and functionally, by a SCOTT Authorized Service Center using SCOTT
Authorized Test Equipment at least every two years. However, heavy use may
require more frequent testing. This recommendation is in addition to all other
cleaning and maintenance procedures.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SCOTT RIT-PAK III and is the answer not in the manual?

SCOTT RIT-PAK III Specifications

General IconGeneral
BrandSCOTT
ModelRIT-PAK III
CategoryRespiratory Product
LanguageEnglish

Related product manuals