SIGMA 2
11
4.8 CYLINDER PRESSURE
1. Open cylinder valve and check
pressure gauge to ensure that cylinder has
a minimum of 80% of the fully charged
capacity:
For 207 bar cylinders - 170 bar.
For 300 bar cylinders - 240 bar.
2. When fully satisfied with apparatus,
proceed to undertake tasks as required.
5. DOFFING
INSTRUCTIONS
5.1 REMOVE FACEMASK
1. On apparatus with a First Breath DV,
take a breath and press the reset button to
close the air supply.
2. Pull tabs on buckles forward to
release the head-harness or head-net.
Remove facemask.
Note:
Instant Air DVs will free flow through mask
until the cylinder valve is closed.