1 Internal Measure
2 Metric/Imperial Selector
3 Locking Screw
4 ABS/0 Switch
5 LCD Display
6 External Measure
7 On/Off Control
8 Zero Control
9 Battery Cover
10 Depth Measure
11 Step Measure
INSTRUCTIONS FOR:
MODEL:
AK9623EV
Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and
properly maintained, give you years of trouble free performance.
IMPORTANT PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS, AND
CAUTIONS. USE THIS PRODUCT CORRECTLY AND WITH CARE, FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO
MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY.
DIGITAL VERNIER CALLIPER 0-300mm/0-12”
WARNING! Ensure Health and Safety, local authority and general workshop practice regulations are adhered to
when using tools and equipment.
 DO NOT use if damaged.
 Maintain calliper in good and clean condition for best performance.
 Keep the work area clean, uncluttered and ensure there is adequate lighting.
Keep children and unauthorised persons away from the work area.
 DO NOT use the calliper for any purpose other than for which it is designed.
 DO NOT get calliper wet or use in damp or wet locations, or areas where there is condensation. Keep calliper clean
and dry using a dry cotton cloth only.
DO NOT dip or submerge the calliper in any type of liquid.
 DO NOT expose calliper to bright sunlight or dust.
 DO NOT disassemble. The calliper must be checked by qualified service personnel only.
 DO NOT apply any voltage to the calliper i.e. with an electric marker pen.
 The calliper is a precision instrument, treat with care, avoid using force and do not subject to knocks or shocks.
 Use in reasonably constant temperature conditions of approximately 20
°
C.
When not in use, turn off and store gauge in a safe, dry, childproof location.
Hardened and tempered stainless steel digital calliper with satin finish. 11mm High figures in LCD display for ease of reading.
Metric and Imperial calibration with conversion between the two. Zero setting control allows for comparative measurement.
Supplied in carry-case.
1. SAFETY INSTRUCTIONS
2. INTRODUCTION & SPECIFICATION
Resolution 0.01mm (0.0005”)
Range 0-300mm (0-12”)
Accuracy ±0.04mm/0.001”
Functions Zero set, mm/inch select, incremental zero
Messages Flashing display = replace battery
Battery life Approx. two years (approx. one year in continuous service)
Battery LR44 - 1.5V
Operational Temperature range 0 - 40°C
1
2
3
4
5
6
7 8
9
10
11
AK9623EV Issue No: 1 - 24/09/08
Question and Answer IconNeed help?

Do you have a question about the Sealey AK9623EV and is the answer not in the manual?

Summary

Safety Instructions and Warnings

Product Overview and Specifications

Digital Vernier Calliper Features

Description of the digital vernier calliper's construction, display, and measurement capabilities.

Operation

Battery Replacement

Summary

Safety Instructions and Warnings

Product Overview and Specifications

Digital Vernier Calliper Features

Description of the digital vernier calliper's construction, display, and measurement capabilities.

Operation

Battery Replacement

Overview

The Sealey AK9623EV Digital Vernier Caliper is a precision measuring instrument designed for accurate measurements in both metric and imperial units. This tool is manufactured to a high standard, ensuring reliable performance over time when properly maintained and used according to the provided instructions.

Function Description:

The primary function of the AK9623EV is to provide precise measurements of internal, external, depth, and step dimensions. It features a hardened and tempered stainless steel construction with a satin finish, contributing to its durability and accuracy. The caliper utilizes a digital LCD display with 11mm high figures, making readings easy to interpret. It offers conversion between metric (mm) and imperial (inches) units, enhancing its versatility for various applications. A key feature is the zero-setting control, which allows for comparative measurements by setting a new zero point at any open position of the caliper. Additionally, it includes an ABS/0 switch for incremental measurements, enabling the user to add a second measurement to a previously taken one, displaying the total.

Important Technical Specifications:

  • Resolution: 0.01mm (0.0005”) – This indicates the smallest increment the caliper can accurately measure, highlighting its high precision.
  • Range: 0-300mm (0-12”) – The caliper can measure objects up to 300 millimeters or 12 inches in length, covering a wide range of common measurement tasks.
  • Accuracy: ±0.04mm/0.001” – This specification defines the maximum permissible error in measurement, assuring users of its reliability.
  • Functions: Zero set, mm/inch select, incremental zero (ABS/0 switch). These functions provide flexibility and ease of use for different measurement scenarios.
  • Messages: A flashing display indicates a low battery condition, prompting the user to replace it.
  • Battery Life: Approximately two years under normal use, or about one year in continuous service. This provides an estimate of the battery's operational duration.
  • Battery Type: LR44 - 1.5V. This specifies the exact battery required for replacement.
  • Operational Temperature Range: 0-40°C. The caliper is designed to operate accurately within this temperature range, ensuring consistent performance in typical workshop environments.

Usage Features:

The AK9623EV is designed for straightforward operation. Before use, all measuring surfaces must be clean. The caliper is turned on by pressing the on/off control, and a brief waiting period (at least one second) is recommended before taking measurements. To ensure accuracy, the locking screw should be loosened, and the caliper closed. If the display does not show zero, the zero control button should be pressed to reset it. Users can select between inch or mm units using the metric/imperial selector, verifying the correct units are displayed. Measurements are then shown directly on the LCD display.

For comparative measurements, a new zero can be established at any open position by pressing the zero control. An advanced feature is the incremental zero function, activated by the ABS/0 switch. After taking a first measurement, pressing the ABS/0 switch will display 'INC', allowing the user to take a second measurement. The display will then show the total of both measurements, which can be useful for cumulative measurements. The caliper includes a locking screw (3) to secure the jaws in place once a measurement has been taken, preventing accidental changes. The physical components include internal measure jaws (1), external measure jaws (6), a depth measure rod (10), and a step measure surface (11), allowing for a comprehensive range of measurement types. The LCD display (5) is central to its digital functionality, providing clear readings.

Maintenance Features:

Proper maintenance is crucial for the longevity and accuracy of the AK9623EV. The caliper should always be kept in good and clean condition for optimal performance. After use, it should be wiped clean and dry using a cotton cloth. It is important to avoid getting the caliper wet or using it in damp locations, or areas with condensation. Submerging the caliper in any liquid is strictly prohibited. Exposure to bright sunlight or dust should also be avoided.

The caliper is a precision instrument and should be handled with care, avoiding force, knocks, or shocks. It should be used in reasonably constant temperature conditions, ideally around 20°C. When not in use, the caliper should be turned off and stored in a safe, dry, childproof location, preferably in its supplied carry-case.

Battery replacement is indicated by a flashing display. To replace the LR44 - 1.5V battery, the battery cover (9) is slid to the right. The exhausted battery is removed, and a new one is fitted with the positive side uppermost. The battery cover is then refitted. Old batteries must be disposed of safely and responsibly, not incinerated, as they may explode. If the display fails to change when the slide is moved, removing the battery for at least 30 seconds and then refitting it can often resolve the issue. Disassembly of the caliper is not recommended and should only be performed by qualified service personnel. Applying any voltage to the caliper, such as with an electric marker pen, is strictly prohibited. Adhering to these safety and maintenance guidelines will ensure the caliper remains accurate and functional for many years.