EasyManua.ls Logo

Sealey G2000I.V2 - OPERATION PROCEDURES; Engine Oil and Fuel Preparation; Engine Starting Sequence

Sealey G2000I.V2
7 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
G2000I.V2 | Issue 1 05/09/16
Original Language Version
© Jack Sealey Limited
capacity. To switch the generator back on , press the DC protector button to “ON”, Direct current will resume.
ReducetheloadoftheconnecteddevicebelowthespeciedratingoutputofthegeneratoriftheDCprotectorturnsoffagain,Stop
using the device and contact authorized stockist.
5.6. Economy Control Switch (ECS)
When the ECS switch is “ON” the economy control unit controls the engine speed according to the connected load. The results are
better fuel consumption and less noise.
WhentheECSswitchis“OFF”theenginerunsattheratedspeed(4500rev/min)regardlessofwhetheraloadisconnectedornot.
Note:- The ECS must be “OFF” when using electrical devices that require a large starting current, such as a compressor or
submersible pump.
5.7. Fuel Tank Cap
Turn the fuel tank cap counter clockwise to remove
Thefueltankcapisprovidedwithanairventknobtoallowfuelow.Theairventknobmustbeturnedto“ON”Thiswillallowfuelto
owtothecarburettorandtheenginetorun.Whentheengineisnotinuseturntheairventknobto“OFF”tostopfuelow.
5.8. Ground (Earth) terminal
When the electrical device is earthed, the generator must always be earthed.
6. OPERATION
6.1. Engine Oil
WARNING! The generator has been shipped without engine oil. DO NOTstarttheengineuntilithasbeenlledwithsufcientengine
oil.
Recommendedengineoil................................................SAESJ15W-40
Recommended engine oil grade................ API Service SE type or higher
Quantity...........................................................................................0.35ltr
6.1.1. Place the generator on a level surface.
6.1.2. Removethescrewsg.2.1andthenremovecoverg.2.2.
6.1.3. Removeoilllercap.
6.1.4. Fillwiththespeciedamountoftherecommendedengineoilreplaceandtightentheoilllercap.
6.1.5. Replace the cover and tighten the screws.
6.2. Fuel
Danger: TheFuelishighlyammable.
8 DO NOToverllthefueltank,asitmightoverow
when the fuel warms up and expands.
9 Use only unleaded petrol. The use of leaded petrol will
cause severe damage to internal engine parts.
WARNING! The generator should be kept in an upright position
when fuel is in the tank.
Recommended Fuel....................................Unleaded Petrol
FuelTankCapacity.....................................................4.0ltr.
6.2.1. Tolltankremovefueltankcapandpourfuelintothetank
uptotheredlineinsidethellertubeg.3.
Maximumfuellevelisshowning.4.
6.3. Starting the Engine
6.3.1. TurntheECSswitch(Bkack)to“OFF”g.5.
6.3.2. Turntheairventknobto“ON”g.6.
g.2
g.3
g.5
g.4
g.6

Related product manuals