Seca 780 - Optional functions; Tare; Hold and Autohold; Replace weight in repeat measurements

Seca 780
22 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
function.
To
initiate
the
function,
another
button
must
be
pressed
when
the
scale
is
started.
The
verification
counter
is
then
displayed
which
is
incremented
whenever
the
scale
is
recalibrated.
It
enables
the
user
to
check
whether
the
scale
was
manipulated.
If,
within
five
seconds,
the
button
is
pressed
longer
than
1.5
s,
the
scale
switches
to
recalibration
mode.
The
scale
now
measures
the
zeropointand
waits
to
be
loaded
with
at
least
Vi
of
the
maximum
load.
By
briefly
pressing
the
button
the
weight
displayed
can
be
decremented
or
incremented
in
steps
of
lOg
until
the
weight
of
the
load
placed
on
the
scale
is
reached.
The
direction
can
be
changed
by
pressing
the
button
longer.
To
stop
recalibration
the
button
must
be
pressed
longer
than
5s.
The
scale
can
be
switched
off
any
time
using
the
on/off
button
or
by
not
actuating
it
for
a
while,
thus
aborting
recalibration.
Optional
functions
The
functions
"Tare",
"Hold",
"Autohold"
and
"Replace
weight
in
repeat
measurements"
and
various
menu
functions
can
be
implemented
via
a
program
on
the
EEPROM
(on
the
weight
measuring
module).
The
functions
are
explained
below:
Tare:
The
tare
function
can
be
assigned
to
a
button
by
the
EEPROM
program.
If
the
button
is
pressed,
the
weight
is
tared
out
as
soon
as
the
display
has
settled,
if
it
is
within
the
permissible
range.
Pressing
the
button
again
alternatively
switches
the
tare
function
off
or
causes
the
weight
to
be
tared
out
again.
Hold
and
Autohold:
If
the
hold
function
is
assigned
to
a
button
by
means
of
the
EEPROM,
the
weight
reading
is
held
on
display
when
the
button
is
pressed
as
soon
as
the
value
has
stabilized.
Alternatively,
the
hold
function
can
be
automated
so
that
the
weight
will
always
be
frozen
when
it
has
exceeded
a
certain
threshold
and
is
stable.
The
hold
function
is
switched
off
after
expiry
of
a
predetermined
time
or
by
pressing
the
button
again.
In
addition
the
scale
can
be
configured
so
that
the
hold
function
will
be
deactivated
when
the
scale
is
relieved,
when
the
scale
is
relieved
and
then
loaded
again
and
/
or
when
the
load
on
the
scale
changes
significantly.
Replace
weight
in
repeat
measurements:
The
scale
can
be
configured
so
that
the
weight
last
displayed
is
displayed
again
in
a
measurement
when
the
scale
detects
that
it
has
been
loaded
with
almostthe
same
weight.
Menu
functions:
Not
all
the
functions
listed
below
can
be
activated
on
the
same
scale.
When
the
menu
button
is
pressed
long
enough,
the
scale
switches
to
the
setting
mode.
Here,
damping
and
weight
display
settings
can
be
made.
When
the
button
is
pressed
briefly,
the
scale
switches
to
function
mode.
The
following
functions
are
possible:
BMI:
From
weight
and
height
the
body
mass
index
is
calculated
using
the
following
formula
BMI
=
weight[kg]
/
length[m]
2
BMI
=
weight
[kg]
/
height
[m]
2
.
IDE:
The
deviation
from
the
ideal
weight
calculated
using
the
formula
0,9
x
(length[cm\
-
100
)
0.9
(height[cm]
-
100)
is
displayed.
UL:
When
a
limit
weight
is
overshot
or
undershot
an
acoustic
signal
is
generated.
DIFF:
The
difference
to
a
second
weight
is
output.
The
second
weight
can
have
been
measured
using
the
autohold
function,
entered
manually
or
stored
when
the
difference
function
was
last
called.
Technical
data
Supply
voltage:
Supply
current:
Quiescent
current:
30-34-00-618
2.7V
-
3V
and
2.7V
-
15V
(via
SeSAM
bus)
typ.
0.5mA
+
power
supply
for
backlighting
(typ.
100mA)
typ.
2pA
3
06.09.1999
EE/Jensen