EasyManua.ls Logo

Seca 780 - EEPROM; Serial bus; Fault handling; Time base

Seca 780
22 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
In
order
to
avoid
measuring
errors
due
to
almost
flat
batteries,
their
voltage
is
measured
at
regular
intervals.
If
the
voltage
drops
below
a
certain
limit,
the
user
is
alerted
by
the
battery
symbol
in
the
LCD.
If
the
next
threshold
is
undershot,
„bAtt"
is
displayed
and
weighing
is
no
longer
possible.
In
order
to
extend
the
on-time
when
the
scale
is
mains
operated,
the
microcontroller
receives
a
signal
when
a
mains
transformer
is
connected.
It
is
possible
to
use
rechargeable
batteries,
but
the
batteries
will
not
be
charged
in
the
scale.
EEPROM
The
DETF
module
accommodates
an
EEPROM
on
which
all
parameters
are
stored
that
can
be
used
to
influence
the
program
sequence,
for
example
various
limit
values
or
the
coefficients
for
determining
the
weight
and
for
temperature
compensation.
Furthermore,
the
scale
can
store
values
to
be
retrieved
when
the
scale
is
switched
on
the
next
time,
e.g.
the
modules
last
connected.
Serial
bus
To
allow
the
scale
to
be
calibrated
and
additional
modules,
such
as
displays,
to
be
connected,
the
DETF
module
is
equipped
with
an
interface
to
the
SeSAM
bus.
On
this
bus
the
stabilized
and
non-stablized
supply
voltages
are
available.
Via
a
data
and
a
clock
pulse
line
all
relevant
data
is
transmitted
to
other
modules.
A
special
start
line
is
provided
via
which
the
scale
can
be
switched
on
or
other
modules
can
signal
thatthey
wantto
send
data.
Fault
handling
If
faults
occur,
the
SeSAM
bus
initiates
a
fault
message
with
the
relevant
fault
code.
Furthermore,
each
fault
message
includes
the
number
of
the
module
type
on
which
the
fault
has
occurred
and
a
code
which
indicates
how
long
the
message
is
to
stay
on
display
and
which
displays
are
to
be
suppressed.
The
fault
messages
are
transferred
to
the
SeSAM
bus
and
can
be
output
by
the
display
module
(module
type
for
the
DETF
module
=
1).
The
following
fault
messages
are
implemented:
10
20
bit
counter
overflow
11
Counts
outside
the
permissible
range
12
Switch-on
zeropoint
outside
the
permissible
range
13
Zero
follow-up
outside
the
permissible
range
14
Fault
in
the
kg
value
calculation
15
Recalibration
fault
20
Battery
voltage
too
low
21
Fault
in
battery
voltage
measurement
22
Fault
in
temperature
measurement
23
Temperature
range
exceeded
(
<
0°C
or
>
50°C)
30
General
bus
fault
32
Command
buffer
full
33
More
than
8
slaves
detected
40
EEPROM
fault
41
Incorrect
EEPROM
access
50
Other
fault
Instead
of
fault
message
20
„bAtt"
is
displayed
and
„temP"
instead
of
fault
message
23.
Time