Short wiring manual basic information
Control Panels PAS8xxControl Panels PAS8xx
Intruder alarm system
SAFETY WARNINGS
The device must be installed in a place with limited access.
Please act according to your local rules and do not dispose of your old product with normal household
waste. The product is covered by European Directive 2002/96/EC.
The device must be connected
––
to an AC power supply with Protective Earthing: Phase or Live line (L) black or brown
cable, Neutral line (N) blue cable, Protective Earth line (PE) green cable with a vertical yellow dash. Double
2
isolated cables with minimum cross-sectional area of 0,75 mm for 230V power supply must be used.
The device uses two power supplies: main and back-up.
2V, 7Ah/20HR capacity, rechargeable hermetically sealed Lead-Acid battery.
Main power supply: a power transformer with:
primary winding: ~230V, 50 Hz;
secondary winding: ~20V, 1.5A, 50Hz.
Back-up power supply: 1
SecoLink intruder alarm system is compliant with the safety requirements of EN 60950-1:2003.
All the above described power supplies linked to the system must comply with the EN 60950-1:2003 safety
requirements.
Additional automatic Two-Pole Circuit Breaker should be installed in an AC electric power circuit in order to prevent
over-current and short circuits.
The circuit breaker contact gap should be no less than 3mm.
The circuit breaker should be placed close to the system's housing and should be easily accessed.
Before performing any work of installation or service ALWAYS disconnect the device from power supplies in
sequence as described below:
- cut off 230 V AC power line with the automatic Two-pole Circuit Breaker;
- disconnect 12V back-up battery by removing battery female plug from Control Panel male socket BAT.
Two-pole Circuit-Beaker installation on flexible cables is forbidden.
General safety requirements:
– do not touch any part of the main power supply under voltage: transformer, a fuse block, connection wires;
– it is forbidden to perform any device installation or service work during lightning;
– use batteries according to manufacturer recommendations. The use of improper battery type may cause an
explosion;
- battery replacement : be sure battery terminals are isolated, battery terminals short-wiring may cause an explosion.
It is not recommended to connect the device to a fully discharged battery. To avoid a malfunction of system use an
adequate charger to charge a new or discharged battery before connecting battery with a device.
Inoperative or expired batteries should be recycled according to the local rules or EU directives 2006/66/EC and
93/86/EEC.
Waste battery collection and returning for utilization separate from household waste is mandatory!
Power supply distribution board
Housing of the Alarm System (device)
Automatic Two-pole
Circuir Breaker
L N
NL
Cable from power
distribution board
AC power cable to the
Alarm System
The Control Panel Terminals TIP, RING, T-1, R-1 should be connected to analog PSTN line. Connection to digital
ISDN line may cause the device damage.
Page 1
The device wiring and service should be performed by trained personnel with sufficient knowledge about the device
and general safety requirements for work with low voltage (up to 1000V) AC power lines. In the case of a device
malfunction repair works can be performed by qualified personnel only.
Question and Answer IconNeed help?

Do you have a question about the SECOLink PAS8 Series and is the answer not in the manual?

SECOLink PAS8 Series Specifications

General IconGeneral
BrandSECOLink
ModelPAS8 Series
CategoryControl Panel
LanguageEnglish

Summary

Safety Warnings and Precautions

General Safety Requirements

Covers warnings on touching live parts, working during lightning, battery use, and disposal.

Power Supply and Circuit Breaker Safety

Details on connecting AC power, protective earthing, and circuit breaker gap requirements.

Installation and Service Personnel

Emphasizes that wiring and service must be done by trained personnel and proper disconnection.

Battery Handling and Disposal

Guidance on battery charging, replacement, and mandatory recycling according to EU directives.

Line Connection Advisory

Advises connecting to analog PSTN lines only and warns against digital ISDN lines.

Wiring Diagrams and System Configuration

Module Wiring Overview

Illustrates serial port connections and general module wiring for PAS8xx systems.

System Template and Default PINs

Explains the default system template, zone usage, and provides default PIN codes for access.

Tamper Function Setup

Details the tamper function and how to enable or disable it for zone Z6.

Data Line and Voltage Specifications

Covers data line length limits and voltage requirements for module operation.

Module Wiring Details

Keypad and Detector Module Connections

Wiring diagrams for keypads (KM20B, KM24) and detector modules (GSV2M, GSV2C).

Expander and Communication Module Wiring

Wiring for expander modules (RCM800) and communication modules (EXM800, LAN800).

Accessory Wiring

Wiring diagrams for accessories like RID820 and PROX8.

Advanced Wiring and System Setup

Outdoor Siren Wiring Safety

Safe wiring of outdoor sirens using PWR15/PWR20, emphasizing isolation from control panel.

PWR20 Bus Repeater Functionality

Details the PWR20 as an additional power supply and bus repeater for security systems.

PIN Restoration Procedure

Step-by-step guide to restoring the default service PIN using a short circuit.

Keypad Attachment and Startup

Instructions for keypad attachment and system startup without AC power.

Zone Wiring Configurations

Single Zone Wiring Types

Wiring methods for single zones using Normally Closed (NC) or Normally Open (NO) contacts.

Double Zone Wiring (PAS832)

Specific wiring instructions for double zones, applicable only to the PAS832 model.

Detector and Relay Wiring Samples

Provides wiring samples for 4-wire smoke detectors and relays.

Module and Transmitter Wiring

GSV2 Module Wiring Options

Illustrates wiring for GSV2 modules, with and without module operation monitoring.

Transmitter Serial Connection

Wiring instructions for compatible transmitters via the serial connector.