Problems Possible causes Methods of repair and checking
The OSCILLATINGWEIGHT
rotates at an abnormally high
rate,andnochargingismade.
1) The COIL of the
GENERATINGCOILBLOCK is
broken.
2) The pivot of the
GENERATINGROTOR is
broken. (The pinion of the
GENERATINGROTORand the
gear of the INTERMEDIATE
WHEELFORGENERATING
ROTOR are out of mesh.)
1) Check the resistance of the
GENERATINGCOILBLOCK.
Replace the GENERATINGCOIL
BLOCK if the COIL is broken.
2) Remove the broken piece of the
GENERATINGROTOR,andreplace
and lubricate the GENERATING
ROTOR. (Overhaul and clean if
necessary.)
The OSCILLATINGWEIGHT
will not rotate.
1) The gear of the
OSCILLATINGWEIGHT and
the pinion of the
INTERMEDIATEWHEELFOR
GENERATINGROTOR are out
of mesh.
2) The pivot of the
GENERATINGROTOR is
broken. (The pinion of the
GENERATINGROTOR and the
gear of theINTERMEDIATE
WHEELFORGENERATING
ROTOR engage with each
other.)
1) If the gear of the OSCILLATING
WEIGHT and the pinion of the
INTERMEDIATEWHEELFOR
GENERATINGROTORareintact,
reassemble them to the movement.
2) Remove the broken piece of the
GENERATINGROTOR,andreplace
and lubricate the GENERATING
ROTOR. (Overhaul and clean if
necessary.)
The current consumption for
the whole of the movement
exceeds the standard value.
1) When the measurement is
made,theICisstillinthe
quickstartmode.(Whenthe
current consumption
measuresabout200μA,itis
likelythattheICisinthequick
start mode.)
2) The load applied on the
geartrain,etc.hasincreased,
and the driving pulse to
compensate it has been
generated.
1)Afterconnectingthetester,move
the OSCILLATINGWEIGHT more
quicklyforalongerperiodoftime,
andthen,makethemeasurement
again.
2) If the current consumption for
the CIRCUIT BLOCK alone is within
thestandardvaluerange,overhaul
andcleanthemovementparts,and
then,makethemeasurementagain.
The current consumption for
the CIRCUIT BLOCK alone
exceeds the standard value.
1) The light from outside the
movement is affecting the
measurement.
2) When the measurement is
made,theICisstillinthe
quickstartmode.(Whenthe
current consumption
measuresabout200μA,itis
likelythattheICisinthequick
start mode.)
3) The IC is out of order.
1)Shutoutthelight,andmakethe
measurement again.
2)SwitchtheICtothenormal
mode,andmakethemeasurement
again.
3) Replace the CIRCUIT BLOCK.
Cal. 5M84A
21/21