[SPECIFICATIONS]
Item
Cal. No.
Power generator
Rechargeable
battery
Monthly rate: less than 15 seconds (worn on the wrist at temperature
range between 5 and 35 ºC)
Nil
Use 10-second gate
Movement: less than 0.80 µA
Circuit block: less than 0.20 µA
Automatic generating system
MT920 Titanium carbon lithium rechargeable battery
0.9V - 2.20V
From full charge to stoppage: approximately 6 months
6 jewels
1/21
PARTS LIST/ TECHNICAL GUIDE
KINETIC Cal. 5M84A
5M84A
Driving system
Additional function
Crown operation
Loss/Gain
Regulation system
Gate time for rate measurement
Current consumption
Power supply
Operating
voltage range
Duration of
charge
Number of jewels
Interval of hands movements
Normal position
1st click position
2nd click position
Coil resistance
• 3hands (Hour/Minute/Second)
•Calendar Date(datedial)
Day (retrograde day indicator)
1 second
Steppingmotor2pieces
• Powerreserveindicator(secondhand)
• Energydepletionforewarningfunction
• Overchargepreventionfunction
• Electroniccircuitresetfunction
• Dayanddatecorrectionfunction
• Secondhandstopfunction
Free
Day and date setting
•
 
Diameter
Outside :
Ø 27.6 mm
Casing :
Ø 27.0 mm
• Height:4.3
mm
Timesetting(HourandMinute)
5
M
8
4
A
Movement
Coil block: 1.70 - 2.10 K
Ω
Generating coil block: 280 - 380
Ω
Question and Answer IconNeed help?

Do you have a question about the Seiko 5M84A and is the answer not in the manual?

Seiko 5M84A Specifications

General IconGeneral
MovementQuartz
Caliber Number5M84
Case MaterialStainless Steel
CrystalHardlex
Water Resistance100 meters
Case Diameter38 mm
Strap MaterialStainless Steel
Dial ColorBlack
FunctionsDate
Power ReserveApproximately 3 years

Summary

Watch Specifications

Interval of hands movements

Specifies the movement interval of the watch hands.

Driving system

Details the mechanism that drives the watch hands.

Additional function

Lists extra functionalities like power reserve indicator.

Crown operation

Explains functions associated with different crown positions.

Loss/Gain

Defines acceptable monthly rate deviation for accuracy.

Regulation system

States the regulation system used by the movement.

Gate time for rate measurement

Specifies the duration for measuring the watch's rate.

Current consumption

Outlines electrical current usage of movement components.

Coil resistance

Provides resistance values for coil blocks.

Power supply

Details the power source, battery type, and voltage.

Number of jewels

Indicates the number of jewels in the movement.

How to Charge the Watch

By Swinging the Watch

Instructions on charging the watch by manual movement.

Using KINETIC Energy Supplyer

Guide for charging with a specialized SEIKO device.

Power Reserve Indicator

Reading the Power Reserve

Explains how to interpret the second hand's position for power reserve.

Parts List - Casing Components

Casing Parts Assembly

Illustrates and lists the components of the watch casing.

Parts List - Calendar and Dial Components

Calendar Mechanism and Dial Parts

Details parts for the calendar and dial assembly.

Parts List - Automatic Generating Mechanism

Automatic Generating and Circuit Parts

Lists components of the automatic generating system and electronic circuit.

Parts List - Gear Train and Setting Mechanism

Gear Train and Setting Mechanism Parts

Details parts for the gear train and setting mechanisms.

Parts List Remarks

Selecting Specific Parts

Guidance on choosing parts based on watch design and caliber number.

Screw Types

Lists common screw part numbers and quantities used in the watch.

Tools and Consumables

Movement Holder

Specifies the universal tool needed for holding the watch movement.

Watch Oils

Lists recommended oils and grease for watch servicing.

Technical Guide - Dial and Hand Setting

Setting the Retrograde Day Hand

Step-by-step instructions for setting the retrograde day hand correctly.

Technical Guide - Battery Unit Service

Battery Unit Identification

How to distinguish battery units for different Cal. 5M Series.

Battery Unit Removal and Installation

Procedures for safely removing and installing the battery unit.

Technical Guide - Circuit Block

Circuit Block Identification

How to differentiate circuit blocks for Cal. 5M8 and 5M6 Series.

Technical Guide - Movement Disassembly Remarks

Removing the Setting Stem

Procedure to remove the setting stem before dismantling.

Setting Mechanism Overview

Illustrates and describes parts of the setting mechanism.

Technical Guide - Gear Train Lubrication

Gear Train and Setting Position

Details wheel settings and lubrication for the gear train.

Technical Guide - Automatic Generating Mechanism Service

Battery Unit Removal and Installation in Generating Mechanism

Steps for removing and installing the rechargeable battery unit within the generating mechanism.

Lubrication of Generating Parts

Guidance on lubricating specific components of the generating mechanism.

Technical Guide - Inspection and Measurement

Measuring Whole Movement Current Consumption

Procedure to measure the total current drawn by the watch movement.

Technical Guide - Circuit Block Current Measurement

Measuring Circuit Block Current Consumption

Procedure to measure the current consumption of the circuit block only.

Technical Guide - Coil Resistance and Generation Check

Checking Coil Resistance

Verifying the resistance values of coil blocks against specifications.

Checking Automatic Generating System

Procedure to test the functionality of the automatic generating system.

Technical Guide - Crown Operations and Checks

Time Setting and Stem Check

How to operate the crown for time setting and check stem security.

Date and Day Setting Check

Procedure for checking date and day correction with crown at 1st click.

Second Hand Stop Function Check

Verifying the second hand stop function when crown is at 2nd click.

Technical Guide - Water Resistance and Accuracy

Water Resistance Testing

Methods and applied pressures for testing water resistance levels.

Accuracy Testing

Procedure for measuring and verifying the watch's accuracy rate.

Technical Guide - Troubleshooting

Oscillating Weight Issues

Diagnosing and resolving problems with oscillating weight rotation and charging.

Current Consumption Issues

Troubleshooting high current consumption for the whole movement or circuit block.