Limestone deposits on the screen
Debris or solids on the screen
Clean with water or replace
Clean or replace
(Warning: do not use tools to remove
the lime deposits because you can
affect the functioning of the venturi;
only use anti lime products)
Clean if possible or Replace
Clean if possible orReplace
Open the water supply outside tap
Check the water supply filter (input
station)
Product is not mixed or not dosed
correctly
The foot filter is clogged
Clean or replace the filter
The calibration nozzle is clogged
Clean or replace the nozzle
Insufficient water pressure
A minimum pressure of 22PSI is
required for
correct operation; if the
pressure is not correct, contact a
plumber
The chemical product container is
empty
Refill or change the chemical product
container
The suction hose is not properly
connected to the elbow fitting
Check that the suction hose is
properly connected to the fitting, use
a clamp for a better grip
The suction hose is crimped
somewhere
Check that the suction hose is
properly positioned
Debris or Solids in the venturi
Clean with water or compressed air
(Warning: do not use tools to remove
the lime deposits because you can
affect the functioning of the venturi;
only use anti lime products)
The nozzle is not fully inserted or
Wrong metering tip
Check that the nozzle is securely
plugged into the non return valve or
select a smaller metering tip
The chemical product container
fills with water.
The non return valve is clogged or
worn
Clean or replace the non return valve