EasyManua.ls Logo

Selmo Electronics MUSA Plus Eco - Safety Precautions and Connections; General Safety Warnings; Electrical Connection Types

Selmo Electronics MUSA Plus Eco
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Comfort technologydivisio
n
“MUSA Plus Eco
Electronic control for towel radiators
Rev. 02
Sept. 201
7
Selmo Electronic
Viia Pacinotti, 24 - 35030 Rubano (PD) Italy- Tel 049.8976761, Fax 049.8976085 - www.selmo.it
EN
Preserve with care the present instruction sheet and read carefully before using the device.
•The present device has been designed for exclusive use on a towel radiator.
•The thermostat is designed for heating the liquid contained inside a towel radiator in
combination with a heating element. Any other use is forbidden.
•Before using, carefully ensure that the line voltage is the same as that specified for the
device (see technical specifications).
•Only use heating elements compatible with the type of used towel radiator.
•Disconnect power supply before cleaning or performing maintenance of the product.
•In case of damage of the power supply cable shut down the device and do not tamper with
it. The damaged power supply cables can be replaced exclusively by the manufacturer or by
an authorized service center. Failure to comply with the above rules could lead to
compromised system safety and void the warranty.
•Store and transport the heating element exclusively in the protecting packaging.
•Replacement of the heating element can be done exclusively by the product manufacturer.
•Children aged under 8 years old and people with reduced physical, sensory or mental
abilities.
•can use the device only under supervision. Children should not play with the device.
•Cleaning and maintenance meant to be carried out by the user should not be done by
children without supervision.
CONNECTIONS TO ELECTRIC MAINS
The available versions are the following:
•1 Schuko plug, UK plug, Swiss plug, Italian plug (Class I or Class II) for direct connection.
•3-wires for Class I models: Live (brown); Neutral (blue); Earth (green-yellow).
•2-wires for Class II models: Live (brown), Neutral (blue).
•3-wires for Class II models with "Fil-Pilote": Live (brown), Neutral (grey), "Fil-Pilote" (black).
WARNING RISK OF ELECTRIC SHOCK!
Disconnect power supply before proceeding with installation.