5.10 Electrical Cabinet
The compressor’s electrical cabinet and the components housed therein should be checked and
cleaned by a licensed electrician every 2,000 hours or 1 year, whichever occurs first. The
external and internal surfaces of the electrical cabinet should be vacuum cleaned and wiped
down with a dry cloth. The electrical components and wiring within the cabinet should be
vacuum cleaned only with particular attention given to the cabinet’s louvre vents.
5.11 Preventative Maintenance Program
Maintenance Task
Maintenance Interval *
8 h 40 h 500 h 1,000 h 2,000 h 4,000 h 8,000 h
Daily Weekly Qtrly 1 Yea
2 Years
Routine O
eration
Check / Top-Up Oil Level ●
Drain Ai
-Oil Receiver Condensate ●
Check Controller and Gauge
Readings
●
Air System
Clean Air Pre-Filters ●
Clean Air Filter Element ●
Clean Oil Cooler and Air After-
Coole
●
Check Safety Valve ●
Replace Air Filter Element ●
Replace Inlet Valve Maintenance
Kit
●
Replace Minimum Pressure Valve
Maintenance Kit
●
Ai
-Oil Receiver Ext. Inspection ●
Oil System
Replace Oil Filte
● Initial ●
Replace Oil ● Initial ●
1
●
2
●
3
Replace Ai
-Oil Separato
●
Replace Thermostatic Valve
Maintenance Kit
●
Drive System
Check / Adjust V-Belt Tension ● Initial ●
Replace V-Belts ●
Regrease Motor Bearings ●
4
●
5
Electrical S
stem
Check Emergency Stop Button ●
Check Electrical Connections ●
Clean Electrical Cabinet ●
Check Motor Insulation (> 1 MΩ) ●
* Compressor running hours or elapsed time, whichever occurs first. In adverse working conditions, such as
dusty environment and / or high temperature, the maintenance intervals should be halved.
1
Using mineral-based compressor lubricating oil; 2,000 hours maximum or 1 year.
2
Using semi-synthetic compressor lubricating oil; 4,000 hours maximum or 1 year.
3
Using fully-synthetic compressor lubricating oil; 8,000 hours maximum or 1 year.
4
Models DS45 to DS90.
5
Models DS8 to DS37.