Instruction Manual
PE-8E
PH/ORP Meter for Industrial Use
CO., LTD.Sensonix Japan
EM07012000
Question and Answer IconNeed help?

Do you have a question about the Sensonix PE-8E and is the answer not in the manual?

Sensonix PE-8E Specifications

Measuring Range and Repeatability IconMeasuring Range and Repeatability
pH measuring range0 ~ 14
pH resolving power0.01 pH
ORP measuring range± 1400 mV
ORP resolving power1 mV
pH repeatability± 0.05
ORP repeatability± 5 mV
Transmission Output IconTransmission Output
Transmission outputDC 4 ~ 20 mA
Maximum load resistance500 Ω
Linearity0.5 %
Control Functions IconControl Functions
Contact output1C Contact Output
CapacityAC250V, 3A max
Control actionON-OFF action
Temperature Compensation IconTemperature Compensation
Temperature compensation elements6.8k Ω(25℃) or 500Ω(25℃)
Temperature compensation range0 ~ 100 ℃
Ambient temperature5 ~ 40 ℃
Power and Dimensions IconPower and Dimensions
Power sourceAC90 ~ 260 ℃ 50 / 60Hz 10W
Outline dimensions96 (W)× 96 H( )× 145 D( )
Weight650 g

Summary

1. Preface

2. Installation

2.1 Installation sites

Recommends suitable locations for meter installation based on environmental conditions.

2.2 Installation way

Details the panel mounting procedure for the meter, including panel cut dimensions.

2.3 Setting Internal Switches

Explains how to configure internal switches (DIG and DIP) for various measurement settings.

3. Wiring

3.1 Wiring of alarm contact output

Guides on connecting alarm contact outputs for ALM1 and ALM2, including capacity and load.

3.2 Wiring of the electrode

Details how to connect pH/ORP electrodes and temperature compensation electrodes to the meter.

3.3 Wiring of transmission output cable

Explains how to connect the transmission output cable for data transmission to receivers.

4. Explanation of each parts

4.1 Operation keys

Describes the function of each key on the front panel of the PE-8E meter.

4.2 Operation lamps

Explains the meaning and behavior of the indicator lamps (MEAS, CAL, DISP, ALM) on the meter.

5. Operation

5.1 Operating procedures

Outlines the initial checks and procedures before starting meter operation and measurement.

5.2 Calibration (For pH meter Use)

Details the automatic and manual calibration procedures for the pH measurement function.

5.3 Calibration (For ORP Meter Use)

Describes the sensitivity check procedure for the ORP electrode using standard materials.

5.4 Parameter Display

Explains how to display and set parameters like ALM values, measured value, and transmission output.

5.5 Renewal of Set Value

Guides on how to renew or adjust set values for parameters on the display.

6. Error codes

6.1 Error codes of pH / ORP meter

Lists and explains various error codes that may appear on the meter display.

6.2 Countermeasures to error codes

Provides solutions and actions to take for specific error codes displayed by the meter.

7. Spare parts

8. Specifications