Control Valve Programming
CLOCK
NEXT
REGEN
SET
CLOCK
NEXT
SET HARDNESS
SET
CLOCK
SET
DAY
SET
CLOCK
NEXT
AM
GAL
Exit
Programming
Mode
The control valve has been pre-programmed from the factory with the correct regeneration cycle program and
cycle times. The gallon capacity between regeneration can be changed by adjusting the water hardness.
Step 1 - Press the NEXT and the UP Arrow buttons at the same time and hold for 3 seconds.
Step 2 - Raw Water Hardness: Adjust to the correct hardness by pressing the UP or DOWN
arrow button. Default setting 20 grains per gallon. Press NEXT to go to Step 3.
Step 3 - Day Override: The factory default setting is 15 days. Press NEXT to go to Step 4.
Step 4 - Regeneration Time: The system regenerates at 2:00 AM. The regeneration cycle should
be set for a time when no water will be used. (Typically this is during the night.) Press the
UP or DOWN arrow buttons to adjust the regeneration hour. Press NEXT to adjust the
regeneration time minutes then press NEXT to exit programming.
REGEN