Twin Meter Alternating Water Softening System
Operation and Maintenance Manual
Series 930TA

Questions and Answers

  • C
    Charles StewartAug 21, 2025
    Why SENTRY II Water Dispenser doesn't regenerate automatically?
    • D
      Dana FordAug 21, 2025
      If your SENTRY II Water Dispenser control valve only regenerates when you manually hold the REGEN button, it could be due to several reasons: * The bypass valve might be in the bypass position. Turn the bypass handles to place the bypass in the service position. * The meter might not be properly connected to the circuit board. Connect the meter to the three-pin connection labeled METER on the circuit board, ensuring a secure connection. * The meter turbine might be restricted or stalled. Remove the meter and check for rotation or foreign material. * The programming might be incorrect. Check for programming errors. * The meter might be defective. Replace the meter. * The circuit board might be defective. Replace the circuit board.
  • C
    cjuarezAug 23, 2025
    What to do if there is excessive water in the SENTRY II Water Dispenser brine tank?
    • S
      saragrayAug 23, 2025
      If you notice excessive water in the brine tank of your SENTRY II Water Dispenser, consider the following potential causes: * Improper program settings: Check the refill setting. * Plugged injector: Remove the injector and clean or replace it. * Drive cap assembly not properly tightened: Re-tighten the drive cap assembly. * Damaged Seal and Spacer Stack Assembly: Replace the Seal and Spacer Stack Assembly. * Restricted or kinked drain line: Check the drain line for restrictions or debris and/or un-kink the drain line. * Plugged backwash flow controller: Remove the backwash flow controller and clean or replace it. * Missing Refill Flow Controller: Replace the Refill Flow Controller.
  • Y
    yjosephAug 26, 2025
    Why is my SENTRY II 930TA using too much salt?
    • P
      Patrick WilcoxAug 26, 2025
      If your SENTRY II Water Dispenser is using too much salt, here are a few things to check: * Improper refill setting: Review and adjust the refill setting. * Improper program settings: Ensure your program settings are specific to your water quality and application needs. * Frequent regeneration: Look for leaking fixtures that may be exhausting capacity, or consider if your system is undersized. * Slow drip from brine refill tubing: The float valve isn't designed to stop a drip; replace the Seal and Spacer Stack Assembly.
  • J
    jeffery25Aug 28, 2025
    Why is water constantly running to drain on my SENTRY II Water Dispenser?
    • R
      Richard MurphyAug 28, 2025
      If water is constantly running to the drain in your SENTRY II Water Dispenser, here are some possible reasons: * A power outage occurred during regeneration. When power is restored, the control valve will finish the remaining regeneration time. Remember to reset the time of day. * The Seal and Spacer Stack Assembly is damaged. Replace it. * There's a piston assembly failure. Replace the piston assembly. * The Drive Cap Assembly isn't tightened properly. Re-tighten it.
  • J
    Jeremy BlakeAug 30, 2025
    What causes a SENTRY II 930TA Water Dispenser control valve to fail to draw brine?
    • U
      ugriffithAug 30, 2025
      If the control valve on your SENTRY II Water Dispenser isn't drawing brine, consider these potential causes: * The injector is plugged: Remove the injector and clean or replace it. * The brine piston is faulty: Replace the brine piston. * There's a brine line tubing connection leak: Inspect the tubing and fittings for air leaks. * Drain line restriction or debris: This can cause excess back pressure on the injector; inspect the drain line and clean to correct the restriction. * The drain line is too long or elevated too high: Shorten the length and/or height. * Low water pressure: Check the incoming water pressure, ensuring it remains at a minimum of 40 psi.
  • M
    Mary AdamsSep 1, 2025
    How to troubleshoot a blank display on my SENTRY II Water Dispenser?
    • S
      Sara MullinsSep 2, 2025
      If there is no display on the Control Valve Circuit Board of your SENTRY II Water Dispenser, check the following: * Ensure there is power at the electrical outlet. Repair the outlet or use a working outlet. * Make sure the Control Valve Power Cord is securely plugged into the Control Valve Circuit Board at both ends. * Verify that the proper voltage is being delivered to the Circuit Board. * The Circuit Board may be defective. Replace the Circuit Board.
  • B
    Brandi JonesSep 4, 2025
    Why is there residual salt in the service lines of my SENTRY II Water Dispenser?
    • A
      Annette RodriguezSep 4, 2025
      If you're finding residual salt in the service lines of your SENTRY II Water Dispenser, here's what to investigate: * Low water pressure: Check the incoming water pressure, ensuring it remains at a minimum of 40 psi. * Incorrect injector size: Replace the injector with the correct size for your application. Refer to the System Specification for the correct size. * Restricted drain line: Check the drain line for any restrictions or debris and clean it.
  • T
    Theresa PotterSep 6, 2025
    How to fix incorrect time on SENTRY II 930TA Water Dispenser Control Valve Circuit Board?
    • B
      Becky LeeSep 6, 2025
      If the Control Valve Circuit Board on your SENTRY II Water Dispenser isn't displaying the correct time, try these steps: * Ensure the Control Valve Power Cord is plugged into an uninterrupted outlet, not one controlled by a light switch. * Reset the Breaker Switch and/or GFI switch if they have tripped. * If there was a power outage, reset the time of day. If your Circuit Board has a battery backup, the battery may be depleted and need replacement. * The Circuit Board could be defective and need replacement.
  • G
    Gary ArmstrongSep 8, 2025
    What to do if SENTRY II Water Dispenser display doesn't show water flowing?
    • S
      Steven FinleySep 8, 2025
      If the display on your SENTRY II Water Dispenser doesn't indicate water flow and “Softening” flashes during water usage, check these: * Ensure the bypass valve is not in the bypass position. Turn the bypass handles to place the bypass in the service position. * Verify the meter is connected to the meter connection on the Circuit Board, ensuring it's securely connected to the three-pin connection labeled METER. * Check for a restricted or stalled meter turbine by removing the meter and inspecting for rotation or foreign material. * The meter might be defective and need replacement. * The Circuit Board could be defective and require replacement.
  • J
    Julie MedinaSep 13, 2025
    Why SENTRY II Water Dispenser doesn't regenerate even when holding REGEN button?
    • D
      David WellsSep 13, 2025
      If your SENTRY II Water Dispenser's control valve doesn't regenerate automatically even when the REGEN button is held down, here are a few potential causes: * Broken Drive Gear or Drive Cap Assembly: Replace the Drive Gear or Drive Cap Assembly. * Broken Piston Rod: Replace the Piston Rod. * Defective PC Board: Defective PC Board

Summary

System Specifications and Warnings

System Specifications

Technical details for water pressure, temperature, electrical needs, and meter performance.

Safety Warnings

Critical precautions for safe operation, installation, and material compatibility.

Installation Instructions

Pre-Installation Checklist

Outlines essential requirements and checks before installing the water softener.

Start-Up Instructions

System Start-Up Procedure

Guides the user through the initial setup and cycling of the water softener system.

Manually Regenerating the Water Softener

Series 930 Control Valve Programming

Service Instructions

Control Valve Trouble Shooting

Troubleshooting Display and Power Issues

Addresses problems like no display, incorrect time, or no water flow indication.

Troubleshooting Regeneration and Water Quality

Covers issues with regeneration, salt usage, and water quality.

Troubleshooting Error Codes

Explains error codes (e.g., Err-1001) and their solutions related to motor movement.