To begin, place the bypass in the position shown in
Figure 1.
Place the softener in the Backwash cycle.
• To place Unit A in the Backwash cycle press and
hold the REGEN button (approx. 6 seconds) until
the control valve initiates a regeneration cycle.
Unit A is now in the Backwash cycle. An initial
burst of air will be released to the drain. Leave
Unit A in the Backwash cycle until the water
running to the drain runs clear.
• Press the REGEN button to advance the
controller to the next cycle. Unit A is now in the
Brine/Slow Rinse cycle.
• When the timer begins countdown press the
REGEN button to advance the controller to the
next cycle. Unit A is now in the 2nd Backwash
cycle.
• When the timer begins countdown press the
REGEN button to advance the controller to the
next cycle. Unit A is now in the Fast Rinse cycle.
Leave Unit A in the Fast Rinse cycle for at least
five minutes.
• After at least five minutes press the REGEN
button to advance the controller to the next cycle.
Unit A is now in the Brine Tank Fill cycle. Leave
the unit in the Brine Tank Fill cycle for at least
five minutes. To speed up the process, fill the
brine tank with water manually. Fill the brine tank
up to a few inches ABOVE the false bottom,
(approx. 6-8 inches).
• After the brine tank has been filled to the proper
level press the REGEN button to advance the
controller to the home position.
Repeat the above instructions for start-up of Unit B.
Note: The Brine Tank Refill instructions have been
completed in the Unit A start-up.
To complete the Start-up place bypass in the position
shown in Figure 2