SPLIT-TYPE ROOM AIR CONDITIONER
Owner’s Manual &
Installation Manual
IMPORTANT NOTE:
Read this manual carefully before installing
or operating your new air conditioning
unit. Make sure to save this manual for
future reference.
Please check the applicable models, technical
data, F-GAS(if any) and manufacturer information
from the “Owner's Manual - Product Fiche ”
in the packaging of the outdoor unit.
(European Union products only)
Question and Answer IconNeed help?

Do you have a question about the Senville SENL-09CD-16 and is the answer not in the manual?

Overview

This document is an Owner's Manual and Installation Manual for a Split-Type Room Air Conditioner. It provides comprehensive information on the unit's specifications, features, installation, operation, maintenance, and troubleshooting.

Function Description

This split-type room air conditioner is designed to provide cooling, heating, and dehumidification for indoor spaces. It consists of an indoor unit and an outdoor unit, connected by refrigerant piping and electrical cables. The unit can be operated via a remote control or manually. It features various operating modes, including COOL, HEAT, DRY, AUTO, and FAN, and offers functionalities like auto-restart, anti-mildew, wireless control (for some units), louver angle memory, and refrigerant leakage detection. The unit is designed to operate within specific temperature ranges, and safety protection features may activate if these ranges are exceeded.

Important Technical Specifications

Operating Temperature Ranges:

  • Inverter Split Type:
    • COOL mode: Room Temperature 17°C - 32°C (62°F - 90°F), Outdoor Temperature 0°C - 50°C (32°F - 122°F). For models with low-temp cooling systems, Outdoor Temperature -15°C - 50°C (5°F - 122°F). For special tropical models, Outdoor Temperature 0°C - 52°C (32°F - 126°F).
    • HEAT mode: Room Temperature 0°C - 30°C (32°F - 86°F), Outdoor Temperature -15°C - 30°C (5°F - 86°F).
    • DRY mode: Room Temperature 10°C - 32°C (50°F - 90°F), Outdoor Temperature 0°C - 50°C (32°F - 122°F). For special tropical models, Outdoor Temperature 0°C - 52°C (32°F - 126°F).
  • Fixed-speed Type:
    • COOL mode: Room Temperature 17°C-32°C (62°F-90°F), Outdoor Temperature 18°C-43°C (64°F-109°F). For models with low-temp cooling systems, Outdoor Temperature -7°C-43°C (19°F-109°F). For special tropical models, Outdoor Temperature 18°C-52°C (64°F-126°F).
    • HEAT mode: Room Temperature 0°C-30°C (32°F-86°F), Outdoor Temperature -7°C-24°C (19°F-75°F).
    • DRY mode: Room Temperature 10°C-32°C (50°F-90°F), Outdoor Temperature 11°C-43°C (52°F-109°F). For special tropical models, Outdoor Temperature 18°C-52°C (64°F-126°F).

Refrigerant Types: The manual mentions R32, R290, and R410A refrigerants. Specific models may use different types. For R290 refrigerant units, the total amount of refrigerant to be charged is no more than:

  • 387g (<=9000Btu/h)
  • 447g (>9000Btu/h and <=12000Btu/h)
  • 547g (>12000Btu/h and <=18000Btu/h)
  • 632g (>18000Btu/h and <=24000Btu/h)

Electrical Specifications:

  • The air conditioner's circuit board (PCB) is designed with a fuse to provide overcurrent protection. The specifications of the fuse are printed on the circuit board.
    • Indoor unit: 3.15A/250VAC, T5A/250VAC, T3.15A/250VAC, T5A/250VAC, etc. (e.g., 9000Btu/h, 12000Btu/h, 18000Btu/h units).
    • Outdoor unit: 120A/250VAC (<=18000Btu/h units), T30A/250VAC (<=18000Btu/h units).
  • Power Cable: H05VV-F or H05V2V2-F (Indoor), H07RN-F (Outdoor).
  • Signal Cable: H07RN-F.
  • Minimum cross-sectional area of power and signal cables are specified based on rated current of appliance (A):
    • 3 and <=6 A: 0.75 mm²

    • 6 and <=10 A: 1 mm²

    • 10 and <=16 A: 1.5 mm²

    • 16 and <=25 A: 2.5 mm²

    • 25 and <=32 A: 4 mm²

    • 32 and <=40 A: 6 mm²

Refrigerant Piping Length: The maximum length of refrigerant piping affects performance and energy efficiency. For a standard pipe length of 5 meters (16.5ft) in North America, and 3 meters in other regions, the refrigerant charge is sufficient. For R290 refrigerant models, no refrigerant can be added, and the maximum length of refrigerant pipe should not exceed 10 meters (32.8ft). Maximum length and drop height of refrigerant piping per unit model are provided in a table based on capacity (BTU/h).

Mounting Plate Dimensions: Different models have different mounting plates. The manual provides diagrams and dimensions for various mounting plate types (Type A, B, C, D, E). The gas side connective pipe diameter is specified as Φ16mm (5/8in) or more, and the wall hole should be 90mm (3.54in).

Outdoor Unit Dimensions and Mounting Distances: A table provides outdoor unit dimensions (W x H x D) and corresponding mounting distances (A and B) for various models.

Usage Features

Display Codes: The indoor unit display shows various codes and indicators:

  • "ECO" when ECO function is activated.
  • "C" when lights up in different color according to the operation mode (some units).
  • " " when Wireless Control feature is activated (some units).
  • "88" displays temperature, operation feature, and error codes:
    • "ON" for 3 seconds when TIMER ON is set.
    • "OFF" for 3 seconds when TIMER OFF is set.
    • "CF" when anti-cold air feature is turned on.
    • "dF" when defrosting (cooling & heating units).
    • "SC" when unit is self-cleaning.
    • "FP" when 8°C heating feature is turned on.
    • " " when ECO feature is activated (some units).
    • " " when wireless control feature is activated (some units).

Operating Modes:

  • COOL mode: For cooling.
  • HEAT mode: For heating.
  • DRY mode: For dehumidification.
  • AUTO mode: Automatically selects operation mode based on room temperature.
  • FAN mode: Circulates air without cooling or heating.

Other Features:

  • Auto-Restart: If power is interrupted, the unit will automatically restart with prior settings once power is restored.
  • Anti-mildew (some units): Prevents mildew growth by operating at very low power to dry up condensed water after COOL, AUTO (COOL), or DRY modes.
  • Wireless Control (some units): Allows control via a smartphone app.
  • Louver Angle Memory (some units): The louver automatically resumes its former angle when turning on the unit.
  • Refrigerant Leakage Detection (some units): The indoor unit displays "EC" or "ELO" or flash LEDs when refrigerant leakage is detected.
  • Sleep Operation: Automatically adjusts temperature to save energy and provide a comfortable sleep environment. The unit will increase/decrease temperature by 1°C (2°F) after 1 hour, and again after another hour. The sleep feature stops after 8 hours.
  • Setting Angle of Airflow: Vertical and horizontal airflow can be adjusted. During COOL or DRY mode, the louver may move to prevent condensation.
  • Manual Operation (without Remote): Allows basic operation if the remote control is lost or not working.

Maintenance Features

Cleaning Your Indoor Unit:

  • Always turn off the air conditioner system and disconnect its power supply before cleaning.
  • Use a soft, dry cloth. For heavy dirt, use a cloth soaked in warm water.
  • Do not use benzene, paint thinner, polishing powder, or other solvents.
  • Do not use water hotter than 40°C (104°F).
  • Rinse the filter with fresh water, then shake off excess water.
  • Dry it in a cool, dry place, away from direct sunlight.
  • Re-clip the air freshening filter to the larger filter, then slide it back into the indoor unit.
  • Close the front panel of the indoor unit.
  • Do not touch air freshening (Plasma) filter for at least 10 minutes after turning off the unit.

Cleaning Your Air Filter:

  • A clogged air conditioner can reduce efficiency. Clean the filter every two weeks.
  • Lift the front panel of the indoor unit.
  • Grip the tab on the end of the filter, lift it up, then pull it towards yourself.
  • Pull out the filter.
  • If your filter has a small air freshening filter, unclip it from the larger filter. Clean this air freshening filter with a hand-held vacuum.
  • Clean the large air filter with warm, soapy water. Be sure to use a mild detergent.

Maintenance – Long Periods of Non-Use: If you plan not to use your air conditioner for an extended period, perform the following:

  • Clean all filters.
  • Turn on FAN function until unit dries out completely.
  • Turn off the unit and disconnect the power.
  • Remove batteries from remote control.

Maintenance – Pre-Season Inspection: Before periods of frequent use, perform the following:

  • Check for damaged wires.
  • Clean all filters.
  • Check for leaks.
  • Replace batteries.
  • Make sure nothing is blocking all air inlets and outlets.

Air Filter Reminders (Optional):

  • Air Filter Cleaning Reminder: After 240 hours of use, the display window on the indoor unit will flash "CL." To reset, press the LED button on your remote control 4 times, or press the MANUAL CONTROL button 3 times.
  • Air Filter Replacement Reminder: After 2,880 hours of use, the display window on the indoor unit will flash "nF." To reset, press the LED button on your remote control 4 times, or press the MANUAL CONTROL button 3 times.