1 SEP LEM012SJ 2015 V01
LEM012SJ DIGITAL DISPLAY KWH METER.
230V | 5(80)A | 50Hz | class 1
DIN rail single phase two wire energy meter
1.1 Safety instruction
1.2 Foreword
1.3 Performance criteria
1.4 Specifications
1.5 Intrinsic errors
1.6 Description
1.7 Dimensions
1.8 Installation
1.9 Operating
1.10 Troubleshooting
1.11 Technical support
User manual

Questions and Answers

Summary

Safety Instructions

Information for Your Own Safety

General safety information for operating the meter and avoiding damages.

Warning

Indicates potential for death, serious injury, or considerable material damage.

Caution

Indicates hazard of electric shock and serious injury.

Qualified Personnel

Defines persons authorized to commission, start up, and label devices.

Use for Intended Purpose

Specifies authorized applications and component compatibility.

Proper Handling

Guidelines for safe transport, storage, installation, and operation.

Exclusion of Liability

Disclaimer regarding accuracy and potential errors in the publication.

Copyright

Legal notice regarding reproduction and use of the document content.

Registered Trademarks

Lists registered trademarks associated with the product.

Foreword

Performance Criteria

Specifications

Intrinsic Errors

Description

Material

Lists the materials used for different parts of the meter.

Dimensions

Installation

Caution

Safety warnings for turning off power and using voltage testers.

Warning

Installation must be by qualified personnel using insulated tools.

Operating

Working Indication

Describes the function of the POWER LED.

Consumption Indication

Explains the PULSE LED and its flash rate.

Reading the Meter

Details how to read energy data on the LCD display.

Indication for Reverse Use

Explains the 'HELP 1' message for incorrect wiring.

Meter Version

How the meter displays its version information.

Pulse Output

Details the pulse output functionality and connection requirements.

Troubleshooting

Caution

Safety precautions during repair and maintenance.

Warning

Requirements for qualified personnel and insulated tools during repair.

Technical Support

Pulse Output Rate Wrong

Contacting support for issues with the pulse output rate.

Overview

The SEP LEM012SJ is a DIN rail single-phase two-wire energy meter designed for measuring electrical energy consumption (kWh). It features a digital display and is suitable for use in various applications, from residential to commercial settings. The meter operates at 230V with a current rating of 5(80)A and a frequency of 50Hz, adhering to Class 1 accuracy standards.

Function Description

The LEM012SJ measures and displays the total energy consumed in kilowatt-hours (kWh) using a 7+1 digit LCD display with a white backlight. This total energy data is non-resettable by the user, ensuring continuous tracking of consumption. The meter is equipped with two indicator LEDs: a POWER LED and a PULSE LED. The POWER LED illuminates when the meter is connected to a power supply and functioning correctly, turning off if there's a fault or no power. The PULSE LED flashes to indicate active energy consumption; a faster flash rate signifies higher consumption. The flash rate is 500 impulses per kWh (2.0Wh/imp), providing a visual representation of energy usage.

Additionally, the LEM012SJ includes a pulse output feature, which is fully isolated from the internal circuitry. This output generates pulses proportional to the measured energy, allowing for remote reading and accuracy testing. The pulse output is a polarity-dependent, passive transistor output that requires an external voltage source (5-27V DC) with a maximum input current of 27mA DC. This enables integration with other systems for data logging or building management.

The meter also incorporates diagnostic features. If the meter is connected incorrectly, with the incoming and outgoing lines reversed, the LCD display will show "HELP 1" every 3 seconds to alert the user to the wiring error. Upon power-up, the meter briefly displays its software version for 3 seconds, such as "UI.00".

Important Technical Specifications

  • Reference Voltage (Un): 230V AC
  • Operational Voltage: 161-300V AC
  • Insulation Capabilities:
    • AC voltage withstand: 2KV for 1 minute
    • Impulse voltage withstand: 6KV – 1.2μS waveform
  • Current Ratings:
    • Minimum current (Imin): 1.0 A
    • Transitional current (Itr): 2.0 A
    • Reference current (Iref): 20 A
    • Maximum current (Imax): 100 A
    • Operational current range: 1.0A - 100A
    • Over current withstand: 3000A for 0.01s
  • Operational Frequency Range: 50Hz ±10%
  • Internal Power Consumption: ≤2W / 10VA
  • Test Output Flash Rate (PULSE LED): 500 pulses per kWh (2.0Wh/imp)
  • Pulse Output Rate (pins 20 & 21): 500 pulses per kWh (2.0Wh/imp)
  • Pulse Supply Current: Ui max=27V / Ii max 27mA
  • Accuracy Class: Class 1 (according to EN 50470-3)
  • Protection Against Penetration: IP51 (dust protected, protected against vertically falling drops of water)
  • Insulating Encased Meter of Protective Class: II
  • Operating Humidity: ≤ 75%
  • Storage Humidity: ≤ 95%
  • Specified Operating Temperature: -10°C - +40°C (3K5)
  • Limit Operating Temperature: -25°C - +55°C (3K6)
  • Storage Temperature: -40°C - +70°C (1K5)
  • Data Display Mode: 7+1 digits for LCD display
  • Data Save: Data can be stored for more than 20 years when power is cut.
  • Dimensions:
    • Height: 140 mm
    • Width: 35 mm
    • Depth: 58.5 mm
    • Weight: 0.20 Kg (net)
  • Material:
    • Front plate: Transparent inflaming retarding polycarbonate
    • Meter cover: Fiber-glass reinforced inflaming retarding polycarbonate
    • Meter base: Fiber-glass reinforced inflaming retarding polycarbonate
    • Protection cover: Fiber-glass reinforced inflaming retarding polycarbonate

Intrinsic Errors:

The meter maintains high accuracy across its operational current range:

  • Imin ≤ I < Itr: Cosφ = 1, ±1.5%
  • Itr ≤ I ≤ Imax: Cosφ = 1, ±1.0%
  • Itr ≤ I ≤ Imax: Cosφ = 0.5L, ±1.0%
  • Itr ≤ I ≤ Imax: Cosφ = 0.8C, ±1.0%

Usage Features

The LEM012SJ is designed for DIN rail mounting (35mm) and should be installed in a dry, well-ventilated location, ideally within a protection box in dusty or dangerous environments. For outdoor installations, a waterproof meter box is required. It is crucial to ensure that the connecting wires are appropriately sized according to local codes and the circuit breaker's ampacity. An external switch or circuit breaker, serving as a disconnection device, must be installed on the inlet wire close to the meter. Similarly, an overcurrent protection device (fuse or thermal cut-off) must be installed on the supply side wire, also near the meter.

The meter's LCD display provides clear readings of total energy consumption. The POWER LED confirms operational status, while the PULSE LED gives a real-time visual indication of energy usage intensity. The pulse output allows for integration into larger energy monitoring systems, providing flexibility for data collection and analysis.

Maintenance Features

Maintenance and repair of the LEM012SJ must only be performed by qualified personnel familiar with applicable codes and regulations. It is imperative to use isolated tools during any work on the meter. Before commencing any work, all power supplying the energy meter and associated equipment must be turned off and locked out, and a voltage sensing device should be used to confirm power is off.

The meter is sealed, and breaking these seals or opening the front cover will void the warranty and may affect the meter's functionality and accuracy. The protection cover must always be placed after installation or maintenance. The warranty period is 12 months from the date of purchase, covering only construction faults. Physical impact or dropping the meter should be avoided, as it contains high-precision components that can be damaged.

Troubleshooting guidance is provided for common issues:

  • No light for the Power supply indicator: Check AC power supply connection, verify correct wiring of terminals 1 and 4, and ensure 230V 50Hz AC voltage is present. If issues persist, contact a qualified technician.
  • No light for the consumption indicator (pulse red): Confirm that a load is running. If the operating power is too low, the LED flash interval will be prolonged, which might give the impression it's not working. If necessary, contact a qualified technician.
  • The register can't run: Check if power is supplied to the meter and if the operating power is too low. If the problem persists, a fault in the internal circuit might be present, requiring a qualified technician.
  • LCD backlight can't lit: Verify power supply to the meter. If there's an internal circuit fault, contact a qualified technician.
  • No pulse output: Check if the external DC power supply (5-27V DC) is connected to the meter and ensure correct wiring (anode to connector 20, cathode to connector 21). If the issue remains, an internal circuit fault may be present, requiring professional assistance.

For further questions or technical support, users are directed to contact their local SEP Europe dealer or distributor via email or phone.

SEP LEM012SJ Specifications

General IconGeneral
BrandSEP
ModelLEM012SJ
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals