6 Divider Removal and Installation
If the divider is removed from the unit, it will function as a single
zone unit, and only one temperature setting will become available.
IMPORTANT!
Every time the divider is removed or installed, the target
temperature will be reset to default value and need to set it
again.
5.ERROR CODES & SOLUTIONS
Error Codes
E1 Low Input-Voltage Error
The Input DC voltage is below the protection setting and the battery protection
is activated.
E2 Fan Error
The cooling fan overloads with more than 1A Current.
E3 Motor Start Error
The motor of compressor is blocked or the pressure difference in the
refrigeration system is too high.
E4 Minimum Motor Speed Error
The compressor overloads and the motor can not maintain its minimum speed.
E5 Ambient Temperature Error
The refrigeration system overloads, or the ambient temperature is too high,
the control is overheated.
E6 Thermal Sensor Fault
Thermal Sensor is open-circuited or short-circuited.
06