SEVENOC DIGITAL LOCK STAND ALONE SETTING MENU
MODEL : M1
1. Function and Operation
1) Administrator information : refers to the administrator’s Passcode or SEVENOC
RFID Card.
2) Unlock information : refers to the input Passcode or SEVENOC RFID Card
information (including administrators and ordinary users).
3) Key “*” : Clear key / Back key. Click the key three times in success exit.
4) Key “#” : Confirmation key or menu function key.
2. Original State
1) The factory administrator initial passcode is 123456, under the initial state any
Passcode or SEVENOC RFID Card can open the lock.
2) Once the new administrator Passcode or SEVENOC RFID Card has been set,
any Passcode and unknown RFID card cannot open the lock.
Question and Answer IconNeed help?

Do you have a question about the SEVENOC M1 and is the answer not in the manual?

Summary

Function and Operation

Administrator Information Definition

Refers to the administrator's Passcode or SEVENOC RFID Card.

Unlock Information Definition

Refers to the input Passcode or SEVENOC RFID Card information for users.

Key * Functionality

Serves as the Clear key or Back key, used for exiting operations.

Key # Functionality

Acts as the Confirmation key or menu function key.

Original State

Factory Default Passcode and Access

Initial state: passcode 123456, allowing any Passcode or RFID Card to open the lock.

Access After New Administrator Setup

After new admin setup, only the new Passcode or RFID Card can open the lock.

Modify Administrator Passcode

Passcode Modification Workflow

Step-by-step guide to change the administrator passcode using the keypad.

Add User Settings

Add User Passcode

Procedure for adding a new user passcode to the digital lock system.

Add SEVENOC RFID Card

Procedure for adding a SEVENOC RFID Card for user access.

Add User Fingerprint

Procedure for adding a fingerprint for user access.

Delete All User Settings

Delete All User Passcode Information

Procedure to remove all user-entered passcodes from the lock.

Delete All User Card Information

Procedure to remove all registered SEVENOC RFID Cards.

Delete All User Fingerprint Information

Procedure to remove all stored user fingerprints.

Other Notes and Warnings

Wrong Passcode Lockout

The keyboard locks for 30 seconds after 5 consecutive wrong passcode entries.

Passcode Peeping Prevention

Function to input extraneous codes before/after the actual passcode.

Automatic Exit

The system automatically exits after 10 seconds of no operation.

Low Voltage Alarm Behavior

Alarm triggers below 4.8V, allowing limited unlocks with delays.

Technical Parameters

Quiescent and Dynamic Current

Specifications for standby and active current consumption.

Capacity and Power

Details on administrator number, passcode/card capacity, and power requirements.

Operating Environment

Specifications for working temperature and relative humidity.

Interface and Passcode Length

Details on the keyboard interface and valid passcode length.

Alarm and Unlock Time

Specifications for low voltage alarm threshold and unlock time.

Overview

This document outlines the setting menu and technical specifications for the SEVENOC Digital Lock, Model M1. It functions as a standalone digital lock with multiple access methods and administrative features.

Function Description

The SEVENOC Digital Lock M1 offers various functionalities for secure access control:

Administrator Information: This refers to the administrator's Passcode or SEVENOC RFID Card, which is used to manage the lock's settings and user access.

Unlock Information: This encompasses any valid input Passcode or SEVENOC RFID Card, including those belonging to administrators and ordinary users, that can unlock the device.

Key Functions:

  • "*" (Clear/Back Key): This key serves as a clear or back function. Pressing it three times in succession will exit the current operation.
  • "#" (Confirmation/Menu Function Key): This key is used to confirm inputs or access menu functions.

Original State:

  • Initial Passcode: The factory default administrator passcode is "123456". In this initial state, any Passcode or SEVENOC RFID Card can open the lock.
  • Security Activation: Once a new administrator Passcode or SEVENOC RFID Card is set, the lock's security is activated, and only registered Passcodes and RFID cards can open it. Unknown RFID cards will no longer work.

Usage Features

The lock offers comprehensive features for managing administrators and users:

Modifying Administrator Passcode:

  1. From the "Initiate State," input "*12#" and press the confirmation key ("#").
  2. Input the current administrator passcode (e.g., "123456#") and press "#".
  3. Input the new administrator passcode (e.g., "456789#") and press "#".
  4. Re-enter the new administrator passcode (e.g., "456789#") and press "#" to confirm.

Adding Users: The lock supports adding users via Passcode, SEVENOC RFID Card, and Fingerprint.

  • Adding Passcode:

    1. Input "*85#" and press "#".
    2. Input the administrator passcode (e.g., "456789#") and press "#".
    3. Input the new user passcode (e.g., "147258#") and press "#".
    4. Re-enter the new user passcode (e.g., "147258#") and press "#" to confirm.
  • Adding SEVENOC RFID Card:

    1. Input "*85#" and press "#".
    2. Input the administrator passcode (e.g., "456789#") and press "#".
    3. The lock will sound "BEEP" three times.
    4. Place the SEVENOC RFID Card against the Card Reader Sensor on the Digital Lock.
    5. "Operation successful" will be indicated.
  • Adding Fingerprint:

    1. Input "*85#" and press "#".
    2. Input the administrator passcode (e.g., "456789#") and press "#".
    3. The lock will sound "BEEP" three times.
    4. Place the user's finger on the Sensor on the Digital Lock.
    5. "Operation successful" will be indicated.

Deleting All User Information: The lock allows for the deletion of all user Passcodes, Card information, or Fingerprint information.

  • Deleting All User Passcode Information:

    1. Input "*71#" and press "#".
    2. Input the administrator passcode (e.g., "456789#") and press "#".
    3. "Operation successful" will be indicated.
  • Deleting All User Card Information:

    1. Input "*69#" and press "#".
    2. Input the administrator passcode (e.g., "456789#") and press "#".
    3. "Operation successful" will be indicated.
  • Deleting All User Fingerprint Information:

    1. Input "*70#" and press "#".
    2. Input the administrator passcode (e.g., "456789#") and press "#".
    3. "Operation successful" will be indicated.

Maintenance Features

The document also provides important notes regarding the lock's operation and maintenance:

Security Features:

  • Wrong Passcode Lockout: If an incorrect passcode is entered more than 5 times consecutively, the keyboard will lock for 30 seconds, and no operations will be possible during this period.
  • Passcode Peeping Prevention: To prevent others from observing your passcode, you can input extraneous codes before and after the actual passcode (e.g., "XXX passcode XXX"). The actual passcode must be included within the input, followed by "#" to confirm.

Operational Efficiency:

  • Automatic Exit: If there is no operation for more than 10 seconds, the system will automatically exit the current menu.

Battery and Low Voltage Alarm:

  • Low Voltage Alarm: When the voltage drops below 4.8V, the lock will automatically trigger an alarm every time it is opened.
  • Post-Alarm Usage: After the low voltage alarm, the lock can still be opened approximately 200 times.
  • Unlock Delay: Once the 200-use limit is exceeded, each unlock operation will have a 5-second delay.
  • Battery Replacement: New batteries must be replaced before the available number of times is exhausted to ensure continuous operation.

Important Technical Specifications

The SEVENOC Digital Lock M1 has the following technical parameters:

  • Quiescent Current: ≤50uA (indicating low power consumption when idle).
  • Dynamic Current: ≤180mA (power consumption during operation).
  • Administrator's Number: Supports up to 9 administrators.
  • Passcode + Card Capacity: Can store up to 300 Passcodes and RFID Cards combined.
  • Power Type: 6V.
  • Emergency Powering: 5VDC (for external power in case of battery depletion).
  • Working Temperature: -25°C to 60°C (suitable for a wide range of environments).
  • Working Relative Humidity: 20% to 90% RH.
  • KBD (Keyboard Type): Touch Standard 12-Bit Keyboard.
  • Passcode Length: 6-8 Bit.
  • Phantom Passcode: 16 Bit (likely referring to the maximum length for the peeping prevention feature).
  • Low Voltage Alarm: 4.8 ± 0.2V.
  • Unlock Time: ≤1 Second (fast unlocking speed).

SEVENOC M1 Specifications

General IconGeneral
BrandSEVENOC
ModelM1
CategoryDoor locks
LanguageEnglish

Related product manuals